Available Quantity | 8 |
Available Conditions | NE SV AR OH |
Classification | Combination and Miscellaneous Instruments - FSC 6695 |
Stock Check Date | 06/24/2025 |
Motional Pickup Transducer
force transducer
excitation 26 vrms, 400 hz; input power 0.120 amp max (each sensor) ; output load 75 k ohms; sensitivy 0.002008 v/v/lbs; temp operating -67 deg f to +160 deg f; dielectric strength 750 vms, 60 hz, 1 min. between winding and case; phase shift +/- 15 deg max w/+/-30 lb