NSN 5925-01-264-7808 NIIN — Circuit Breaker

National Stock number : 5925-01-264-7808

Circuit Breaker


Available Quantity 5
Available Conditions NS
Classification Circuit Breakers - FSC 5925
Schedule B 8536200040
Stock Check Date 05/03/2024
Part-Number.info Quality System
  •   ISO 9001:2015 + AS9120B Certifed
  •   Audited supply chain
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   HAZMAT Certified
  •   ITAR and DDTC Registered
AS9120 Certified Supplier

Product Properties


Description

Circuit Breaker

Body Style

single pole type

Bushing Length

0.464in. and 0.526in.

Body Length

1.969in. and 2.031in.

Body Width

0.735in. and 0.765in.

Case Material

plastic

Center To Center Distance Between Terminals Parallel To Length

1.499in. and 1.561in.

Nonturn Device Location

at 12 oclock

Nonturn Device Radius

0.641in. and 0.671in.

Nonturn Device Length

0.115in. and 0.145in.

Nonturn Device Diameter

0.138in.

Switch Contact Arrangement

single pole, double throw

Fragility Factor

moderately rugged

Mounting Surface To Terminal End Distance

2.232in.

Pole Quantity

1

Arc Quenching Method

magnetic blowout

Mounting Facility Type And Quantity

1 threaded bushing w/panel seal

Storage Type

general purpose warehouse

Thread Quantity Per Inch

32

Maximum Continuous Load Current Rating Per Pole

5.0 amperes dc single location

Operating Voltage Type And Rating Per Pole In Volts

50.0 dc single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

2000.0 dc single location

Circuit Protection Type

overcurrent single location

Trip Release Method

magnetic single location

Trip Release Characteristic

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

125.0 single location

Reset Method

manual

Main Contact Tripping Mechanism Type

trip free

Manual Actuator Type And Quantity

1 toggle

Actuator Function

TRIP-Reset

Internal Trip Release Configuration

series trip single location

Nominal Thread Size

0.500in. ⁓1/2"

Switch Location And Position Designation

internal at pole one

Trip Delay Time In Seconds Per Rated Continuous Current

0.130 at 200 pct single location and 1.500 at 200 pct single location

Inclosure Protection Type For Which Designed

fungus resistant

Switch Terminal Type

tab, solder lug

Switch Current Rating And Type In Amps

10.0 ac and 2.0 dc

Switch Voltage Rating And Type In Volts

250.0 ac and 50.0 dc

Thread Series Designator

un

Terminal Type And Quantity

2 tab w/screw

Pricing and Availability Quote

Review your quote then place an order for this NSN

National Stock Number
5925-01-264-7808
Quantity:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name: