Product Properties


Description

Circuit Breaker

Body Style

single pole type

Body Length

2.510in.

Body Width

0.730in. and 0.780in.

Case Material

plastic

Center To Center Distance Between Terminals Parallel To Length

1.660in. and 1.960in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

2.046in. and 2.078in.

Switch Contact Arrangement

single pole, double throw

Fragility Factor

moderately rugged

Boss Height

0.109in. and 0.171in.

Mounting Surface To Terminal End Distance

2.800in.

Pole Quantity

1

Arc Quenching Method

magnetic blowout

Mounting Facility Type And Quantity

2 threaded hole

Storage Type

general purpose warehouse

Thread Quantity Per Inch

32

Maximum Continuous Load Current Rating Per Pole

5.0 amperes dc single location

Operating Voltage Type And Rating Per Pole In Volts

50.0 dc single location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

2000.0 dc single location

Circuit Protection Type

overcurrent single location

Trip Release Method

magnetic single location

Trip Release Characteristic

time delay single location

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

125.0 single location

Reset Method

manual

Main Contact Tripping Mechanism Type

trip free

Manual Actuator Type And Quantity

1 toggle

Actuator Function

TRIP-Reset

Actuator Position Designation

at pole one

Auxiliary Switch Function And Quantity

1 alarm

Internal Trip Release Configuration

series trip single location

Nominal Thread Size

0.138in. ⁓9/64"

Switch Location And Position Designation

internal at pole one

Trip Delay Time In Seconds Per Rated Continuous Current

0.600 at 200 pct single location and 8.000 at 200 pct single location

Inclosure Protection Type For Which Designed

shock resistant and vibration resistant

Switch Terminal Type

tab, solder lug

Switch Current Rating And Type In Amps

10.0 ac and 2.0 dc

Switch Voltage Rating And Type In Volts

250.0 ac and 50.0 dc

Test Data Document

81349-MIL-C-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.) .

Thread Series Designator

unc

Terminal Type And Quantity

2 threaded stud

Specification/standard Data

81349-MIL-C-55629/2 government specification