Product Properties


Description

Circuit Breaker

Body Style

MULTIPOLE-Multiple actuator type

Mounting Slot Width

0.164in.

Body Length

5.800in.

Body Width

3.168in.

Body Height

2.609in.

Case Material

plastic

Center To Center Distance Between Terminals Parallel To Length

3.547in.

Center To Center Distance Between Terminals Parallel To Width

1.026in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

4.781in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

1.026in.

Fragility Factor

moderately rugged

Boss Height

0.218in.

Pole Quantity

3

Arc Quenching Method

magnetic blowout

Mounting Facility Type And Quantity

6 threaded hole and 6 slot

Storage Type

general purpose warehouse

Special Handling Feature

magnetic

Thread Quantity Per Inch

32

Maximum Continuous Load Current Rating Per Pole

2.0 amperes ac first LOCATION2.0 amperes ac second LOCATION10.0 amperes dc third location

Operating Voltage Type And Rating Per Pole In Volts

480.0 ac first LOCATION480.0 ac second LOCATION28.0 dc third location

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

5000.0 ac first LOCATION5000.0 ac second LOCATION5000.0 dc third location

Circuit Protection Type

overcurrent all locations

Trip Release Method

magnetic all locations

Trip Release Characteristic

time delay all locations

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

125.0 all locations

Reset Method

manual

Main Contact Tripping Mechanism Type

trip free

Manual Actuator Type And Quantity

3 toggle

Actuator Function

TRIP-Reset

Actuator Position Designation

at each pole

External Actuator Linkage Arrangement

one, two, and three linked

Internal Trip Release Configuration

series trip all locations

Nominal Thread Size

0.138in. ⁓9/64"

Trip Delay Time In Seconds Per Rated Continuous Current

0.150 at 200 pct all locations and 0.600 at 200 pct all locations

Inclosure Protection Type For Which Designed

fungus resistant and moisture resistant

Frequency In Hertz

50.0 first location or 60.0 first LOCATION50.0 second location or 60.0 second location

Unpackaged Unit Weight

2.000 pounds

Thread Series Designator

unc

Terminal Type And Quantity

6 threaded stud