NSN 5925-00-391-0914 NIIN — Circuit Breaker

National Stock number : 5925-00-391-0914

Circuit Breaker


Available Quantity 2
Available Conditions AR NS
Classification Circuit Breakers - FSC 5925
Schedule B 8536200040
Stock Check Date 02/02/2026
Part-Number.info Quality System
  •   ISO 9001:2015 + AS9120B Certifed
  •   Audited supply chain
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   HAZMAT Certified
  •   ITAR and DDTC Registered
AS9120 Certified Supplier

Product Properties


Description

Circuit Breaker

Body Style

MULTIPOLE-Single actuator type

Body Length

4.125in.

Body Width

3.344in.

Body Height

3.375in.

Case Material

plastic

Center To Center Distance Between Terminals Parallel To Length

2.625in.

Center To Center Distance Between Terminals Parallel To Width

1.125in.

Unthreaded Mounting Hole Diameter

0.216in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

0.625in.

Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

2.938in.

Fragility Factor

moderately rugged

Boss Height

0.125in.

Pole Quantity

3

Arc Quenching Method

air

Mounting Facility Type And Quantity

2 unthreaded hole

Storage Type

general purpose warehouse

Special Handling Feature

magnetic

Maximum Continuous Load Current Rating Per Pole

30.0 amperes ac all locations

Operating Voltage Type And Rating Per Pole In Volts

500.0 ac all locations and 250.0 dc all locations

Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

5000.0 ac all locations and 2500.0 dc all locations

Circuit Protection Type

overcurrent all locations

Trip Release Method

thermal all locations

Trip Release Characteristic

instantaneous all locations and time delay all locations

Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

138.0 all locations

Reset Method

manual

Main Contact Tripping Mechanism Type

trip free

Manual Actuator Type And Quantity

1 toggle

Actuator Function

TRIP-Reset

Actuator Position Designation

at pole two

Internal Trip Release Configuration

series trip all locations

Trip Delay Time In Seconds Per Rated Continuous Current

10.000 at 200 pct all locations and 200.000 at 200 pct all locations

Inclosure Protection Type For Which Designed

shock resistant and vibration resistant

Trip Release Ambient Temp Rating

50.0 deg celsius all locations

Special Features

circuit breaker supplied with two 12-24 mounting screws 4.125 in. lg

Frequency In Hertz

60.0 all locations

Terminal Type And Quantity

6 quick disconnect, female

Pricing and Availability Quote

Review your quote then place an order for this NSN

National Stock Number
5925-00-391-0914
Quantity:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name: