Serving our customers with quality and safety first.
24.0
-25.0/+85.0 deg celsius
100.00 mm
65.00 mm
51.00 mm
0.5
analog and digital
analog and digital
programmable fieldbus controller
64 max no of nodes with scanner; ca 6000 max no of i/o points, depends on master; max length of bus line 100-500 m; baud rate 125, 250, and 500 kbaud; buscoupler connection 5 pole male connector series 231, mcs; female connector 231-305/010-000/050-000 is included; programming WAGO-I/O-Pro 32; operating temperature 0-55 deg c; weight ca 195 g; realtive humidity 95 pct no condensation
combines the functionality of the ethernet fieldbus coupler with the fuctionality of a programmable logic control, plc
A self-contained item which permits the transfer of information between various types of computer support equipment and computers which would not otherwise be compatible. Excludes modem, communication; expander card, computer, automatic data processing; circuit card assembly; and cable assembly (as modified).
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.