NSN 6540-01-512-1557 NIIN 015121557 — Slit Ophthalmic Light

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6540-01-512-1557
6540015121557
Description:
LIGHT,SLIT,OPHTHALMIC
NSN Assigned:
25-AUG-03
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6540-01-512-1557 Specification Set by the OEM (see RNCC code 3)

Voltage Rating In Volts ASXH:

120.0 ac

Mounting Method AXGY:

base

Part Name Assigned By Controlling Agency CXCY:

G5 ultra opthalmic slit lamp

Special Features FEAT:

converging optics; precision fingertip milimeter SLIT-Width adjustment; halogen illuminatuin; patient headrest; SINGLE-Handed elevation system; EASY-TO-Reach tilt mechanism; DIA-In continuously varialbe aperature settings from 10mm to 0.2mm; adjustable focus fixation light; rheostat next to joystick; five built in filters (s cobalt) ; hruby lens kit optional; SIX-Degree converging binocular yubes with galilean parallel magnification changer; FIVE-Step magnification range from 6.3x to 40x with single knob adjustment and no eyepiece change; tonometer mount optional; dual port beamsplitter allows assistantscope to be attached

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
LL-H52-5358
Cage Code:
66736
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1150/G5 ULTRA
Cage Code:
63381
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1150G5
Cage Code:
63381
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
LL-H52-5358
Cage Code:
66736
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1150/G5 ULTRA
Cage Code:
63381
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1150G5
Cage Code:
63381
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
LL-H52-5358
Cage Code:
66736
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1150/G5 ULTRA
Cage Code:
63381
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
1150G5
Cage Code:
63381
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
34764
FIIG:
A06300
Concept No.:
App. Key:
CF
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "LIGHT,SLIT,OPHTHALMIC"

An item which consists of an illuminating unit and a binocular magnifier or microscope. Designed to permit independent manipulation of either unit, so that the anterior segment of a living eye can be examined.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6540-01-512-1557 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.