NSN 6530-01-224-1324 NIIN 012241324 — Heat And Moisture Lab Sterilizer

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6530-01-224-1324
6530012241324
Description:
STERILIZER,HEAT AND MOISTURE LAB
NSN Assigned:
13-JAN-86
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, Air Force, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6530-01-224-1324 Specification Set by the OEM (see RNCC code 3)

Mounting Type AAXX:

stand

Overall Length ABHP:

34.500in. ⁓34-1/2"

Overall Height ABKW:

23.000in. and 53.000in.

Overall Width ABMK:

28.000in.

Current Type ACDC:

ac

Inside Width ADJT:

15.250in.

Inside Length ADJU:

26.000in.

Inside Height AFMQ:

15.000in.

Accessory Components And Quantity AKYD:

stainless steel PULL-Out tray, 1

Voltage Rating AMSE:

220.0 volts and 240.0 volts

Heating Method BDWT:

electrical

Heat Transfer Method BRXN:

pressure steam

Closure Method CPMD:

hinged door secure by locking lever

Part Name Assigned By Controlling Agency CXCY:

sterilizer heat&moisture labile med INSTR220/240v 23/53X34.5X28"

Special Features FEAT:

reaches 260 deg f in approx 30 min from a cold start, approx 15 min from a warm start; 50/60 hz; SINGLE-Phase power; chamber pressure 34 psi

Material MATL:

steel, corrosion resisting

Material MATT:

steel corrosion resisting

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
6530-00-L00-5034
Cage Code:
89875
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Part Number:
051-772
Cage Code:
1WXG8
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
A67-004805
Cage Code:
46308
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Part Number:
MAGNA-CLAVE
Cage Code:
46308
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
27019
FIIG:
T265-C
Concept No.:
App. Key:
CC
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "STERILIZER,HEAT AND MOISTURE LAB"

An apparatus designed to provide gas or other means of sterilization of heat and moisture labile medical instruments and supplies.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6530-01-224-1324 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.