01-567-7987
Cardio Balloon Dilation Catheter
20.0mm overall length jet coated tip, shaft, guidewire lumen reduces friction; burst pressure to 18 bar; kink resistant; tapered tip; dual lumen shaft; rapid inflate/deflate; french sheath size 5
01-567-7989
Cardio Balloon Dilation Catheter
20.0mm overall length sheath french size 5; jet coated tip, shaft, guidewire lumen, reduces friction; kink resistant; burst pressure up to 18 bar; tapered tip; dual lumen shaft; rapid inflate/deflate
01-567-7990
Cardio Balloon Dilation Catheter
80.0mm overall length jet coated tip, shaft, guidewire lumen reduces friction; burst pressure to 18 bar; kink resistant; tapered tip; dual lumen shaft; rapid inflate/deflate; french sheath size 5
01-567-7991
Cardio Balloon Dilation Catheter
40.0mm overall length jet coated tip, shaft, guidewire lumen reduces friction; burst pressure to 18 bar; kink resistant; tapered tip; dual lumen shaft; rapid inflate/deflate; french sheath size 5
01-567-7992
Cardio Balloon Dilation Catheter
40.0mm overall length jet coated tip, shaft, guidewire lumen reduces friction; burst pressure to 18 bar; kink resistant; tapered tip; dual lumen shaft; rapid inflate/deflate; french sheath size 5
01-567-7993
Ureteral Catheter
Hsg catheter, 13mm dia inflated; w/2.4ml air volume; 10mm dia inflated w/0.8ml saline; accepts 0.035 in guidewire; non latex balloon; open end soft distal tip minimizes uterine cavity trauma; color coded stopcocks on catheter lumens; designed for dye injected uterus/fallopian tube xrays/sonograms flexible, straight
01-567-7994
Biopsy Needle
Used on pro-mag/ultra-pro mag 12.5 automatic biopsy instruments. 250.0mm overall length 18g by 25 cm, pkg of 10 pro-mag bipsy needles; color coded hub; echogenic tip for accurate ultrasound breast, thyroid,
01-567-8363
Rongeur
Rongeur lumbar kerrison ss 5mm bite 8in l 40 deg up lumbar rongeur; for use in neurosurgery for spinal trauma; operative end detachable from handle; 5 mm bite; 40 deg angle up; shaft length: 8 in
01-567-9880
Vascular-nonvas Balloon Catheter
Hyperglide balloon micro
01-567-9910
Drill Endoscopic Bit
Used on knee arthroscopy. cannulated drill bit acl, pcl drill guide system components
01-567-9911
Drill Endoscopic Bit
Used on knee arthroscopy. cannulated drill bit acl, pcl drill guide system components
01-568-0193
Hand Operated Resuscitator
Resuscitator, manual single patient use; disposable; compact; one-way valve
01-568-0255
Bone Screw
Bio rci screw size 9 x 25mm
01-568-0256
Bone Screw
Used on knee arthoscopy. titanium suture post
01-568-0955
Catheters Chest
Suction catheters systems help reduce oxygen desaturation by allowing constant patient vetilation
01-568-0956
Catheters Chest
Suction catheters systems help reduce oxygen desaturation by allowing by allowing constant patient ventilation
01-568-0957
Catheters Chest
Suction catheters systems help reduce oxygen desaturation by allowing constant patient ventilation
01-568-0958
Tracheal Tube
High volume, low pressure cuff
01-568-0959
Tracheal Tube
High volume, low pressure cuff
01-568-0960
Tracheal Tube
High volume, low pressure cuff
01-568-0961
Tracheal Tube
High volume, low pressure cuff
01-568-0962
Tracheal Tube
High volume, low pressure cuff
01-568-1239
Aneurysm Clip
Clip aneurysm yasargil phynox perm 10mm blade 90 deg angle ster permanent; 10.0 mm blade; 90 degree angled; phynox (co-cr-ni) alloy; non-magnetic; mri safe up to 3 tesla; 5.6 mm max opening; 200 gm (1.96 n) closing force; can be resterilized provided it has not made contact with a patient prior to resterilization
01-568-1275
Aneurysm Clip
Clip aneurysm yasargil phynox 7mm blade 90 deg angle ster permanent; 7.0 mm blade, 90 deg angled; non-magnetic; mri safe up to 3 tesla; phynox (co-cr-ni) alloy; 4.5 mm max opening; 200 gm (1.96 n) closing force; can be resterilized provided it has not made contact with a patient prior to resterilization
01-568-1294
Aneurysm Clip
Clip aneurysm yasargil phynox perm 5mm blade 90 deg angle ster permanent; 5.0 mm blade, 90 deg angled; non-magnetic; mri safe up to 3 tesla; 5.6 mm max opening; phynox (co-cr-ni) alloy; 200 gm (1.96 n) closing force; can be resterilized provided it has not made contact with a patient prior to resterilization
01-568-1489
Aneurysm Clip
Clip aneurysm yasargil phynox temporary 20mm blade straight ster temporary; 20.0 mm blade, straight; phynox (co-cr-ni) alloy; non-magnetic; mri safe up to 3 tesla; 11.4 mm max opening; 90 gm (0.88 n) closing force; can be resterilized provided it has not made contact with a patient prior to resterilization
01-568-2267
Bone Surgery Arthroscopic Bur
Single use; sterile; for soft tissue
01-568-2380
Ophthalmology Vitrectomy Kit
Anterior vicrectomy
01-568-2990
Aneurysm Clip
Clip aneurysm yasargil perm 10.2mm blade slightly curved yasargil aneurysm clip, permanent; 10.2mm blade; slightly curved; co-cr-ni alloy material; non-magnetic ; sterile; mri safe up to 3 tesla; 7.5mm masiumu opening; 180 gm closing force; color coding with silver spring
01-568-3016
Aneurysm Clip
Clip aneurysm yasargil prem 15.3mm blade slightly curved yasargil, permanent; 15.3mm blade; slightly curved; co-cr-ni alloy material; non-magmetic; sterile; mri safe up to 3 tesla; 9.8mm opeining; 200gm blosing force; color coding with silver spring
01-568-3025
Aneurysm Clip
Clip aneurysm yasargil temp 15mm blade straight yasargil, temporary, 15.0 mm blade, straight, co-cr-ni alloy, non-magnetic, sterile: mri safe up to 3 tesla, 9.2 mm opening, 70 gm closing force
01-568-4717
Drill Sleeve Screw Fixati Insert
Used on 6515-01-384-9030, implant and instrument set for screw fixation, 6515-01-584-1951 periarticular lcp plating system. insert drill sleeve 4.5mm/3.2mm ss f/drill screw fixation implant se 4.5mm/3.2mm insert drill sleeve; for long 4.5mm lag screws; accepts 3.2mm drill bits
01-568-5397
Vena Cava Filter Implant Set
Filter inferior vena cava trap-ease vena cava filter used to help prevent pulmonary embolism that occurs when blood clots break free from the peripheral circulation
01-568-6808
Vena Cava Filter Implant Set
Filter inferior vena carva trap-ease vena carva filter used to help prevent pulmonary embolism that occurs when blood clots break free from the peripheral circulation
01-568-7162
Trocar Kit
Used on operating room equipment. separator access system non-threaded cannulas with seal no stopcock; disposable trocar system with universal seal for separator access system; this part number will replace C0901- same product in a different configuration allowing the use of less p ackages; 12 in a box
01-568-7163
Trocar Kit
Used on operating room equipment. threaded separator dual pack this part number will replace C0527-essentially the same product packaged in a different configuration; you will only require 1 package versus 3 of the old part number; 10 in a box
01-568-7998
Angiography Catheter
100.0mm overall length guide wire diameter 0.038 in; size 5
01-568-7999
Angiography Catheter
100.0mm overall length guide wire diameter 0.038 in; size 5
01-568-8000
Angiography Catheter
100.0mm overall length guide wire diameter 0.038 in; SIZE6
01-568-8001
Angiography Catheter
125.0mm overall length guide wire diameter 0.038 in; size 5
01-568-8002
Angiography Catheter
70.0mm overall length guide wire diameter 0.038 in; size 6
01-568-8003
Angiography Catheter
100.0mm overall length guide wire diameter 0.038 in; size 6
01-568-8004
Angiography Catheter
100.0mm overall length guide wire diameter 0.038 in; size 5
01-568-8005
Cardiovascular Cathet Guide Wire
Lunderquist extra stiff curved wire guide
01-568-8006
Cardiovascular Cathet Guide Wire
Lunderquist extra stiff wire guide
01-568-8007
Vascular Graft Tube
40.0mm overall length diam 16X08mm; microvel knitted double velour vascular graft; provides blood-tight seal for optimal hemostasis
01-568-8008
Vascular Graft Tube
40.0mm overall length diam 18X10mm; microvel knitted double velour vascular graft; provides blood-tight seal for optimal hemostasis
01-568-8009
Vascular Graft Tube
40.0mm overall length diam 18X09mm; microvel knitted double velour vascular graft; provides blood-tight seal for optimal hemostasis
01-568-8010
Vascular Graft Tube
40.0mm overall length diam 20X10mm; microvel knitted double velour vascular graft; provides blood-tight seal for optimal hemostasis
01-568-8011
Vascular Graft Tube
40.0mm overall length diam 22X11mm; microvel knitted double velour vascular graft; provides blood-tight seal for optimal hemostasis