NSN 6515-01-453-4003 NIIN 014534003 — Defibrillator/monitor-recorder S

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6515-01-453-4003
6515014534003
Description:
DEFIBRILLATOR/MONITOR-RECORDER S
NSN Assigned:
27-FEB-98
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6515-01-453-4003 Specification Set by the OEM (see RNCC code 3)

Furnished Items AFJH:

ecg cable, 1 ea; defiib paddlles, 2 ea (1 pediatric and 1 adult) ; monitoring electrodes, 24 sets; pacing electrodes, 10 sets; nicad battery, 4 ea; recorder paper, 6 rolls; applicable power cables, and operator/service manual, 2 ea; conductive pads, 3 sets

Part Name Assigned By Controlling Agency CXCY:

defibrillator monitor recorder: 120/230v 50/60hz ac or dc

Special Features FEAT:

with pacing; portable; both line and battery powered; auxillary power supply 110 vac, 50 hz; battery charger supply 110/220 vac, 50/60 hz; dual voltage rated; c/o: NON-Invasive pacemaker, defibrillator, ecg monitor, recorder, and external batterty charger; unit is impact resistant and operable in wet environments; the recorder shall annotate at a : time, date, heart rate, pacer parameters, defibrillator parameters, gain and lead; shall have six adjustable discrete energy steps including, but not limited to, 10, 50, 100, 200, 300 and 360 joules; external pacemaker shall have NON-Invasive cardiac pacing rates from 40 through 150 beats/minute; uses disposable, PRE-Gelled electrodes; demand pacemaker capable of asynchronous operation; delivered output current is continuously adjustble over the range of 0-140 milliamps

Supplementary Features SUPP:

note: reusable padded storage case was waived for the purchase. aeromedically certified for fixed wing, wide body aircraft only.

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
804200-59
Cage Code:
28494
RNCC:
3
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
LIFEPAK 10-59
Cage Code:
28494
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
SP0200-98-D-8013
Cage Code:
28494
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
00-0454
Cage Code:
89875
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
47731
FIIG:
A23800
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "DEFIBRILLATOR/MONITOR-RECORDER S"

A collection of items designed for use in the diagnosis and treatment of patients with cardiac arrest, arrhythmia, and those on an electrocardiograph monitor. May include monitor recorder module, defibrillator module, external paddles, external cable, cassette, electrodes, ruler, stylus, chart paper, and the like. May be mounted to field litter and field bed.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
Z
LVL_C:
LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

LVL B Code (LVL_B) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6515-01-453-4003 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.