8 french by 20 cm radiopaque polyurethane TWO-Lumen indwelling catheter with blue flextip, removable LUER-Lock injection caps and extension line clamps, 1; 0.89 mm diameter by 60 cm dual purpose marked SPRING-Wire guide (straight soft tip on one end - j tip on other) with arrow advancer, 1; vessel dilator; 25 gage by 2.54 cm needle, 1; 22 gage by 3.81 cm needle, 1; 18 gage by 6.35 introducer needle, 1; 18 gage by 6.35 cm radiopaque catheter over 20 gage needle, 1; 3 cc syringe, 1; 5 cc syringe, 1; 5 cc arrow raulerson syringe, 1; pressure tranduction probe, 1; fenestrated drape, 1; 10 by 10 cm gauze pads, 5; 5 by 5 cm guaze pads, 2; POVIDONE-Iodine swabsticks, 3; POVIDONE-Iodine ointment, 1 gram, 1; lidocaine hci, 5 ml 1%, ampule, 1; no.11 blade disposable scalpel, 1; 3-o silk suture with straight needle, 1; catheter clamp with fastener, 1; csr wrap, 1
sterile
disposable
arrow TWO-Lumen central venous catheterization kit; individually wrapped; 5 kits per case
It consists of a catheter and other items which may include needles, dilators, syringe and a spring guide wire. Designed for infusion of multiple solutions, and venous pressure monitoring and blood sampling.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.