NSN 6515-01-366-9801 NIIN 013669801 — Respirometer

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6515-01-366-9801
6515013669801
Description:
RESPIROMETER
NSN Assigned:
05-NOV-92
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, Air Force, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6515-01-366-9801 Specification Set by the OEM (see RNCC code 3)

Component And Quantity ALPC:

spiro guard 1; metal adapter 3; safety harness 1; standard zippered carrying case 1

Disposition After Initial Use ANGD:

reusable

Material And Location ANNQ:

steel, corrosion resisting

Part Name Assigned By Controlling Agency CXCY:

respirometer 70X60Mm inlet & outlet conn 22mm male crs with case

Special Features FEAT:

dial dia. 35 mm; 2 dials, small dial reords 0-1 liter, large dial 0-100 liters; size 70 mm x 60 mm; weight 135 gm; has a slide type on/off switch and pushbutton reset; inlet and outlet connection 22 mm male; accuracy porm 2 pct at 16 lpm; for measurement of minute volumes as well as tidal volumes of ventilators and respirators

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
MARK 8
Cage Code:
0VPL3
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Part Number:
92-10-13-20
Cage Code:
66735
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Part Number:
F92I123
Cage Code:
66735
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Part Number:
2756
Cage Code:
0VPL3
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Part Number:
2756
Cage Code:
0YW92
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
47271
FIIG:
T133-K
Concept No.:
App. Key:
KT
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "RESPIROMETER"

An instrument designed for use in measuring minute and tidal volume of ventilators. May include carrying case, adapters and two concentric dials.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6515-01-366-9801 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.