NSN 6515-01-360-2132 NIIN 013602132 — Blood Sample Collecting Kit

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6515-01-360-2132
6515013602132
Description:
BLOOD SAMPLE COLLECTING KIT
NSN Assigned:
20-JUN-92
DEMIL:
NO
Shelf Life:
30 months
UOM:
1 PG
Using Services:
Navy, Air Force, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6515-01-360-2132 Specification Set by the OEM (see RNCC code 3)

Unit Package Quantity AGUC:

100

Component Quantity AJJW:

10

Nonsupply Items And Quantities AJKD:

5bag, ICE-1; label, PATIENT-1; needle, clear hubbed, 20 gage by 1-1/2 in.-1; needle, clear hubbed, 22 gage by 1 in.-1; pad, GAUZE-2; syringe, polypropylene, coated with sodium heparin, usp, 5 ML-1; tip, stopper, self VENTING-1; wipe, ALCOHOL-1; wipe, IODOPHOR-1

Sterility AKMX:

sterile

Disposition After Initial Use ANGD:

disposable

Part Name Assigned By Controlling Agency CXCY:

blood sample collecting kit arterial 10 comp sterile disp 100s

Exterior Container Weight ECWT:

4.00 pounds

Exterior Container Cubic Measure EXME:

1.40 cubic feet

Exterior Container Quantity EXQT:

1

Special Features FEAT:

arterial; individually sealed

Unit Of Issue Cube SUCB:

1.40 cubic feet

Supplementary Features SUPP:

note f, subject to damage by freezing

Unit Of Issue Weight SUWT:

4.00 pounds

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
4039-1
Cage Code:
52087
RNCC:
3
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
N0-045
Cage Code:
89875
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
42830
FIIG:
A23800
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "BLOOD SAMPLE COLLECTING KIT"

An item designed to collect a blood sample from a patient for invitro arterial blood gas analysis. It consists of prepacked tray containing a hypodermic needle, syringe and other suitable components. Excludes blood collecting unit, laboratory; and blood collecting culture unit, laboratory.

Related NSNs

Related NSN
Service
OOU
JTC
Phrase
Related NSN:
6515-01-092-7620
Service Code:
OOU:
AAA
JTC:
Phrase Code:
7
Phrase Code 7

Indicates that the item represented in the input/output header is the preferred replacement item master nsn in the i&s family and is suitable for the item(s)in segment h. use the item represented by the nsn in segment h if technically acceptable for your specific application. the replacement item, master nsn in the i&s family, will be issued when the supply of the replaced item(s) is exhausted. must be used in combination with phrase code f.

  Relationship Codes

OOU: Order of Use. Three position alpha code denoting the interchangeability and substitutability (I&S) relationship of a national stock number within a service/agency I&S family.

JTC: Jump to Code. Three position alpha code that denotes an exception to the normal sequence to be followed in the attrition of items within an interchangeability and substitutability (I&S) family.

Phrase Code: A one position code assigned to a phrase used in the management data list to denote changes and/or relationships between national stock numbers and reference data.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPACG00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6515-01-360-2132 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.