NSN 6515-01-326-1588 NIIN 013261588 — Venous Pressure Monitoring Set

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6515-01-326-1588
6515013261588
Description:
MONITORING SET,VENOUS PRESSURE
NSN Assigned:
20-SEP-90
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, Air Force, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6515-01-326-1588 Specification Set by the OEM (see RNCC code 3)

Component And Quantity ALPC:

introducer needle 1; straight/curved SAFE-T-J double flexible tipped wire guide, cres 1; introducer, radiopaque 1; PEEL-Away sheath, radiopaque polytetrafluoroethylene 1; dacron cuff (optional) 1; catheter, double lumen, radiopaque silicone 1; luer lock plugs 2; injection caps 2; 25 ga needle 1; 22 ga needle 1; lidocaine; POVIDONE-Iodine solution; prep sponges; fenestrated drape 1; gauge sponges; disposable syringes 2; disposable scalpel 1; suture w/needle 1; needle ointment; csr wrap 1; prep tray 1

Features Provided CBBL:

sterile and disposable

Part Name Assigned By Controlling Agency CXCY:

monitoring set venous press 25 comp 7fr cath 20cm lg ster disp

Special Features FEAT:

catheter 7.0 fr, 20 cm l; sheath 10 cm l; introducer 8.0 fr, 14 cm l; used f/venous pressure monitoring/hyperalimentation

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
90-8-6-75 CC
Cage Code:
66735
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Part Number:
F90G113
Cage Code:
66735
RNCC:
5
RNVC:
1
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:
Part Number:
C-HASDY-701J-RSC
Cage Code:
29317
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
KX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
38219
FIIG:
T107-A
Concept No.:
App. Key:
AR
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "MONITORING SET,VENOUS PRESSURE"

A preassembled group of items which are used in invasive blood pressure monitoring of a vein. Excludes monitoring set, arterial pressure and monitoring set, vascular pressure.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6515-01-326-1588 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.