NSN 6515-01-054-1130 NIIN 010541130 — Intrave Catheter And Needle Unit

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6515-01-054-1130
6515010541130
Description:
CATHETER AND NEEDLE UNIT,INTRAVE
NSN Assigned:
14-JAN-78
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 PG
Using Services:
Navy, Air Force, VA, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6515-01-054-1130 Specification Set by the OEM (see RNCC code 3)

Design Designation ANEH:

intravenous

Tip Type ANFG:

beveled

Connector Type ANFJ:

luer lock hub

Nominal Diameter ANHF:

16.000 gage

Needle Nominal Diameter ANHM:

16.000 gage

Needle Nominal Length ANHP:

2.625in.

Catheter Nominal Length ANHQ:

2.500in.

Material And Location ANNQ:

metal hub and plastic, polytetrafluoroethylene catheter and steel, corrosion resisting needle

Part Name Assigned By Controlling Agency CXCY:

catheter & ndl unit D12 iv 16GAX2.50" cath 16GAX2.625" ndl 200s

Special Features FEAT:

MICRO-Vented plug, flask chamber, color coded; unit pkg qty 200

Style Designator STYL:

intravenous catheter and needle unit

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
4452
Cage Code:
60279
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
54
Status:
A
MSDS:
SADC:
Part Number:
4402
Cage Code:
60279
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
54
Status:
A
MSDS:
SADC:
Part Number:
4402
Cage Code:
25650
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
75
Status:
A
MSDS:
SADC:
Part Number:
4452
Cage Code:
25650
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
75
Status:
A
MSDS:
SADC:
Part Number:
CATHLON IV PLACEMENT UNIT
Cage Code:
25650
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
75
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
29491
FIIG:
A22100
Concept No.:
App. Key:
FA
Cond. Code:
1
Status:
A
STYLE DESIGNATOR INTRAVENOUS CATHETER AND NEEDLE UNIT style nsn 6515-01-054-1130
STYLE DESIGNATOR INTRAVENOUS CATHETER AND NEEDLE UNIT style nsn 6515-01-054-1130

Definition Definition of approved item name (AIN): "CATHETER AND NEEDLE UNIT,INTRAVE"

An item consisting of a cannulated needle with an intravenous catheter, and it may contain additional components, such as a hypodermic syringe, needle guard, flow control plug, and the like. The catheter is inserted into the vein by way of the needle's puncture, and is left in position for continued intravenous administration after the needle is withdrawn. A syringe, when supplied, is used to better control insertion of the catheter needle unit or for blood aspiration.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
2.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
LVL_C:
LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6515-01-054-1130 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.