NSN 6515-00-381-9105 NIIN 003819105 — Oxygen And Humidity Therapy Tent

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6515-00-381-9105
6515003819105
Description:
TENT,OXYGEN AND HUMIDITY THERAPY
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
No qup EA
Using Services:
Navy, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6515-00-381-9105 Specification Set by the OEM (see RNCC code 3)

Accessory Components And Quantity AKYD:

rigid plastic headboard, 1; ice chamber, 1; collapsible metal frame, 1; transparent canopy, 1; water reservoir, 1; combination vaporizer, 1; combination VAPORIZER-Nebulizer, 1; 8 ft. oxygen hose, 1

Size Designation ALJP:

infant

Features Provided CBBL:

transparent

Part Name Assigned By Controlling Agency CXCY:

tent oxygen & humidity therapy model d unit

Special Features FEAT:

pediatric use; supplies high humidity and aerosol therapy w/or w/out detergents, nebulization therapy w/antibiotics and oxygen therapy w/normal humidity; ice cooled; for pressure regulator order 6680-01-174-6276 and for hood 6515-00-104-8395

Material MATT:

plastic and steel corrosion resisting

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
0100075
Cage Code:
2A614
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
14240
FIIG:
T087-D
Concept No.:
App. Key:
DA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "TENT,OXYGEN AND HUMIDITY THERAPY"

An item having a vaporizing chamber and nebulizer. For items without these components, see tent, oxygen.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
MPPWN00001
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
Z
LVL_B:
Z
LVL_C:
LVL A Code (LVL_A) Z

Special requirement. see specific instructions or drawings provided.

LVL B Code (LVL_B) Z

Special requirement. see specific instructions or drawings provided.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6515-00-381-9105 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.