2.300in.
6.000in. ⁓6-1/64"
operating
nontripod mounting
smoke
PLUG-In, 2 wire, MULTI-Sensor detector, photoelectric (for smoke) and thermal sensing units; compatible with mxl family of control panels; electrically compatible with existing mxl detector accessories; requires p/n 500-095687, model DB-11C (mounting base, series 11) for some older mxl systems; dust resistant; field cleanable photo chamber; solid state, NON-Mechanical thermal sensor; micro processor based electronics; model FPI-32 programmer/tester (not included) used to electronically program and verify detectors address; FPI-32 allows user to change device from FP-11C to older detector id without having to reprogram control panel; MULTI-Color led flashes green for normal condition, amber for detector fault, and red, when instructed by panel, for alarm condition; capable of BI-Directional communication with control panel; current requires 0.750 amps; plus 32 to plus 100 deg. f operating temp; 0 to 93 percent humidity NON-Condensing; ulc listed
fire detection unit, checks for smoke and thermal variations, relaying data to control panel
FP-11C
A device designed to detect the presence of predetermined amounts of smoke, dust, and the like, within the measuring area. The presence of any of these substances causes a change in the output signal of the device, which relays a warning message back to a central panel. The device itself does not provide any audible or visible output, or analyze chemical content. Excludes alarm, smoke, automatic.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.