NSN 6210-01-443-4290 NIIN 014434290 — Electric Light Control

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6210-01-443-4290
6210014434290
Description:
CONTROL,ELECTRIC LIGHT
NSN Assigned:
10-APR-97
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6210-01-443-4290 Specification Set by the OEM (see RNCC code 3)

Width ABGL:

3.600in.

Depth AEJZ:

1.750in.

Usage Design ALBY:

indoor

Features Provided CBBL:

adjustable light intensity actuation control

Inclosure Material CQSJ:

plastic

Operating Function And Method CQYW:

actuation light intensity and deactuation timer and actuation sound vibration

Voltage In Volts And Current Type CSBH:

40.0 dc

Part Name Assigned By Controlling Agency CXCY:

sensor switch (corner or wall mounted wide view)

Special Features FEAT:

2for use on accessible ceiling; for classroom; large conference room; corner mount; uses pir (passive infrared) in combination with fresnel lens, to detect a change in motion and temperature; white in color; 120 degree COVERAGE2 pole, 1 amp ea

Height HGTH:

3.000in.

Style Designator STYL:

SELF-Contained

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
WVR-PDT-2P
Cage Code:
0J6U2
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
WVR-PDT-2P
Cage Code:
0J6U2
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
01870
FIIG:
A07600
Concept No.:
App. Key:
B
Cond. Code:
2
Status:
A
STYLE DESIGNATOR SELF-CONTAINED style nsn 6210-01-443-4290

Definition Definition of approved item name (AIN): "CONTROL,ELECTRIC LIGHT"

An item specifically designed to remotely control the intensity and/or the on-off operation of a light or lights used for general illumination. May be manually operated and/or actuated by the degree of surrounding light intensity or sound vibration. Do not use for autotransformers, rheostats, or switches which are used without the addition of other parts to accomplish this function.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
51
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6210-01-443-4290 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.