NSN 6150-01-533-8902 NIIN 015338902 — Electrical Outlet Power Strip

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6150-01-533-8902
6150015338902
Description:
POWER STRIP,ELECTRICAL OUTLET
NSN Assigned:
29-SEP-05
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Marines, Army

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6150-01-533-8902 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

7.000in. ⁓7-1/64"

Overall Height ABKW:

1.750in.

Overall Width ABMK:

19.000in.

Ac Voltage Rating ACYN:

120.0 volts or 240.0 volts

Mating End Quantity AFQW:

17

End Item Identification AGAV:

tactical air defense radar system (tadrs)

Current Rating In Amps AMPS:

20.0

Overload Rating In Amps AQAM:

20.000

Current Interrupting Capacity AQAY:

20.0 amperes

Outlet Type ARZG:

switched

Mounting Method AXGY:

rack

Features Provided CBBL:

circuit overload protection device and high inrush protection and spike protective

Body Material CQRG:

steel

Special Features FEAT:

also operates at 50.0 hertz; outlets 16 iec 320 - C13 female; 4 outlets front and 12 on back; outlets in groups of 4, rated up to 250.0 volts 15.0 amperes by ul/csa. and 250.0 volts 10 amperes by vde. standards; 1 iec 320 C20 male power inlet rated at 125.0 volts 20 amperes or 250.0 volts 16.0 amperes by ul/csa. and 250.0 volts 16.0 amperes by vde. standards; EMI-Rfi filtering; 12.0 volt dc indicator light on condition; electromagnetic breaker long time delay curve; MULTI-Stage spike and surge suppression response time approximately 50.0 nanoseconds

Frequency In Hertz FREQ:

60.0

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
PS402737-05
Cage Code:
35181
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
TPC2104
Cage Code:
70513
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
9Z
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
41122
FIIG:
A501P0
Concept No.:
App. Key:
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "POWER STRIP,ELECTRICAL OUTLET"

An enclosed item consisting of one or more connector, receptacle, electrical, mounted on a common mounting. It is designed to be electrically connected to a power supply cable or cord which may be included. It may consist of one or more of the following accessories in various combinations; alarms, circuit breakers, switches and the like that control/protect the device. It may be permanently mounted.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6150-01-533-8902 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
A
ESD:
A
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) A

No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
SMS
SOS:
MMAC:
MCC:
B2
Source of Supply (SOS) SMS

Defense logistics agency, enterprise business systems

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.

Solicitation History DLA solicitations for NSN 6150-01-533-8902

Solicitation
Ends
Qty
AMSC
Buyer
PR
SMB
Solicitation:
SPE4A618T1349
End Date:
10/12/2017
Qty:
2 Ea
AMSC:
1
Buyer Code:
TeamD
PR:
0071104885
SMB:
0%