NSN 6150-01-494-0884 NIIN 014940884 — Electrical Load Bank

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6150-01-494-0884
6150014940884
Description:
LOAD BANK,ELECTRICAL
NSN Assigned:
06-DEC-11
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6150-01-494-0884 Specification Set by the OEM (see RNCC code 3)

Special Features FEAT:

provides temorary load for field servicing and testing 200volt 400hz ground power units; height: 11.000in. ; inclosure: single item w/housing; length: 22.000in. ; operating test capability: ampere meter range 0-250A; volt meter 0-250Vac; frequency meter range 360-440Hz; air cooled and self contained; 4 three phase bal load steps:18; 36; 54; and 72kw; phase indicator and rotation lights; thermal protection; folding handle and carrying case; width: 8.000in.

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
L-72
Cage Code:
0GHG1
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
33776
FIIG:
T228-A
Concept No.:
App. Key:
AA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "LOAD BANK,ELECTRICAL"

A set (bank) of electrical elements that are passive (resistive, inductive, capacitive) or active (motors, batteries). They are usually located adjacent to each other to form a consolidated set of any of these elements or any combination of them. A load bank is used to replace distributed or dispersed load elements contained in a power distribution system or electrical network for the purpose of providing a concentrated load. A load bank contains all the essential electrical characteristics necessary to terminate the circuit and functions in the same manner as the load which it is intended to replace. This description necessarily includes a bank of light bulbs or cone heating elements where energy conversion is primarily in the form of heat although visible radiant energy is the natural result of incandescent heating. Load banks are intended to cover a specific range of characteristics and normally operate at dc or at power frequencies 50, 60, or 400 hz ac. Load banks may be uninstrumented or complete with integral instrumention and may also be furnished as skid or trailer mounted. Excludes test set, electrical (as modified). see also dummy load, electrical.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6150-01-494-0884 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Solicitation History DLA solicitations for NSN 6150-01-494-0884

Solicitation
Ends
Qty
AMSC
Buyer
PR
SMB
Solicitation:
SPE4A619T026G
End Date:
12/12/2018
Qty:
5 Ea
AMSC:
D
Buyer Code:
PARES
PR:
0077442503
SMB:
100%
Solicitation:
SPE4A619T8282
End Date:
11/26/2018
Qty:
1 Ea
AMSC:
D
Buyer Code:
PARES
PR:
0077226641
SMB:
0%
Solicitation:
SPE4A615TBZ78
End Date:
05/29/2015
Qty:
8 Ea
AMSC:
D
Buyer Code:
PARFK
PR:
0058678357
SMB:
100%