NSN 6145-01-311-6386 NIIN 013116386 — Special Purpose Electrical Cable

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6145-01-311-6386
6145013116386
Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL
NSN Assigned:
01-DEC-89
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
500 FT
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6145-01-311-6386 Specification Set by the OEM (see RNCC code 3)

Cross-sectional Shape Style AAGR:

round

Temp Rating ABJH:

105.0 deg celsius

Cross Section Outside Diameter ADVL:

0.250in.

Conductor Quantity AMQN:

2

Accessory Wire Type And Quantity AWTB:

1 drain

Strand Quantity Per Conductor BLNZ:

7 all conductors

Conductor Form CXCW:

stranded all conductors

Round Conductor Size CXDC:

16 awg all conductors

Strand Awg Size Per Conductor CXDG:

24 all conductors

Conductor Arrangement And Quantity CXDQ:

1 twisted pair

Color HUES:

yellow 1st position jacket cable

Material MATT:

plastic polyester 1st position shield foil cable

Surface Treatment SFTT:

aluminum 1st position shield foil cable

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
5SE00491-26
Cage Code:
80020
RNCC:
C
RNVC:
1
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
9F
Part Number:
P/ALPTWK-1-16FKX
Cage Code:
99195
RNCC:
C
RNVC:
1
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
P/APLTW-16-FKX
Cage Code:
99195
RNCC:
C
RNVC:
1
DAC:
6
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
P/ALPTW-16F-KX
Cage Code:
1QPM7
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
P/ALPTW-16-FKX
Cage Code:
99195
RNCC:
3
RNVC:
9
DAC:
E
RNAAC:
KZ
Status:
A
MSDS:
SADC:
Part Number:
5SE00491-26
Cage Code:
28638
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
KZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
16488
FIIG:
A077A0
Concept No.:
App. Key:
AD
Cond. Code:
1
Status:
A
CROSS-SECTIONAL SHAPE STYLE ROUND style nsn 6145-01-311-6386

Definition Definition of approved item name (AIN): "CABLE,SPECIAL PURPOSE,ELECTRICAL"

Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to cable, telephone; cable, power, electrical; cable, radio frequency or cord, electrical. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see cable assembly, special purpose, electrical.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.1000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6145-01-311-6386 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.