NSN 6145-01-168-3140 NIIN 011683140 — Special Purpose Electrical Cable

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6145-01-168-3140
6145011683140
Description:
CABLE,SPECIAL PURPOSE,ELECTRICAL
NSN Assigned:
15-DEC-83
DEMIL:
NO
Shelf Life:
N/A
UOM:
500 FT
Using Services:
Marines, Air Force

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6145-01-168-3140 Specification Set by the OEM (see RNCC code 3)

Cross-sectional Shape Style AAGR:

round

Temp Rating ABJH:

-57.0 deg celsius and 80.0 deg celsius

Cross Section Outside Diameter ADVL:

0.720in.

Conductor Quantity AMQN:

54

Color Coding Document AWXS:

7849790-03538 specification

Strand Quantity Per Conductor BLNZ:

7 all conductors

Conductor Form CXCW:

stranded all conductors

Round Conductor Size CXDC:

24 awg all conductors

Strand Awg Size Per Conductor CXDG:

32 all conductors

Conductor Arrangement And Quantity CXDQ:

27 twisted pair

Conductor Grouping Arrangement Type And Quantity CXDY:

27 twisted pair all groups

Special Features FEAT:

psixth grouping arrangement eleventh and twelfth conductor through TWENTY-Seventh grouping arrangement FIFTY-Third and FIFTY-Fourth conductor and each twisted pair contains one white conductor and one green conductor

Material MATT:

plastic polyolefin 1st position primary insulation all conductors

Surface Treatment SFTT:

tin core conductor all conductors

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
D-200-27-RF2-PU
Cage Code:
04569
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
KZ
Status:
A
MSDS:
SADC:
Part Number:
D-200-27-RF2-PU
Cage Code:
55014
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
KZ
Status:
A
MSDS:
SADC:
Part Number:
7849790P001
Cage Code:
03538
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
7849790P1
Cage Code:
03538
RNCC:
7
RNVC:
2
DAC:
A
RNAAC:
KZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
16488
FIIG:
A077A0
Concept No.:
App. Key:
AD
Cond. Code:
1
Status:
A
CROSS-SECTIONAL SHAPE STYLE ROUND style nsn 6145-01-168-3140

Definition Definition of approved item name (AIN): "CABLE,SPECIAL PURPOSE,ELECTRICAL"

Two or more individually insulated conductors (solid or stranded) contained in a common covering, or two or more individually insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering or shield; each having characteristics not completely conforming to cable, telephone; cable, power, electrical; cable, radio frequency or cord, electrical. Includes items having the combined characteristics of two or more of the aforementioned names. Refers to bulk quantities only; for items of definite length with processed ends or terminated in fittings, see cable assembly, special purpose, electrical.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.3000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
51
LVL_A:
Q
LVL_B:
Q
LVL_C:
6
LVL A Code (LVL_A) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

LVL C Code (LVL_C) 6

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 3.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6145-01-168-3140 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
SMS
SOS:
MMAC:
EH
MCC:
SOS:
SMS
SOS:
MMAC:
MCC:
B2
Source of Supply (SOS) SMS

Defense logistics agency, enterprise business systems

Material Management (MMAC) EH

Electronic components (engineering support at the 88th ose/oss)

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.