NSN 6145-01-079-2574 NIIN 010792574 — Power Electrical Cable

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6145-01-079-2574
6145010792574
Description:
CABLE,POWER,ELECTRICAL
NSN Assigned:
30-JUN-79
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6145-01-079-2574 Specification Set by the OEM (see RNCC code 3)

Cross-sectional Shape Style AAGR:

round

Cross Section Outside Diameter ADVL:

0.355in.

Conductor Quantity AMQN:

2

Conductor Form CXCW:

solid all conductors

Round Conductor Size CXDC:

10 awg all conductors

Conductor Arrangement And Quantity CXDQ:

2 singles

Voltage Rating CXFK:

600.0 root mean square (rms) operating voltage all conductors

Special Features FEAT:

suitable for direct earth burial application

Material MATT:

copper core conductor all conductors

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
2C10-600VARM
Cage Code:
81341
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
48
Status:
A
MSDS:
SADC:
Part Number:
2C10-600VARMFAAE2013A2TYPE2
Cage Code:
81341
RNCC:
5
RNVC:
2
DAC:
4
RNAAC:
48
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00232
FIIG:
A077A0
Concept No.:
App. Key:
AB
Cond. Code:
1
Status:
A
CROSS-SECTIONAL SHAPE STYLE ROUND style nsn 6145-01-079-2574

Definition Definition of approved item name (AIN): "CABLE,POWER,ELECTRICAL"

Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.

6145-01-079-2574 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
N
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality N

The item does not have a critical feature such as tolerance, fit restrictions or application. nuclear hardness properties have not been determined (not valid for input).

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
G69
SOS:
MMAC:
MCC:
Source of Supply (SOS) G69

Department of transportation federal aviation administration attn: coe aml-030 tsf bldg 215 po box 25082 oklahoma city, ok 73125-0082

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.