NSN 6135-01-550-2518 NIIN 015502518 — Wet Primary Battery

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6135-01-550-2518
6135015502518
Description:
BATTERY,WET,PRIMARY
NSN Assigned:
13-APR-07
DEMIL:
NO
Shelf Life:
36 months
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6135-01-550-2518 Specification Set by the OEM (see RNCC code 3)

End Item Identification AGAV:

sat amrel, marcom ivcs

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
735709091
Cage Code:
0KAG7
RNCC:
3
RNVC:
2
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
ZZJMG
SADC:
Part Number:
735709070
Cage Code:
0KAG7
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
ZZKDM
SADC:
Part Number:
73570905
Cage Code:
0KAG7
RNCC:
5
RNVC:
9
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
10388807
Cage Code:
A486G
RNCC:
6
RNVC:
9
DAC:
9
RNAAC:
WF
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
08404
FIIG:
T139-A
Concept No.:
1
App. Key:
AC
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "BATTERY,WET,PRIMARY"

An item consisting of one or more primary cells constructed to produce an electromotive force by electrochemical action. It is not efficiently rechargeable and requires the addition of electrolyte in fluid form to become usable. Excludes battery, water activated; battery, dry; and battery, storage.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
32
LVL_A:
E
LVL_B:
Q
LVL_C:
X
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 32

Type i, shelf life.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6135-01-550-2518 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
Y
PMIC:
A
ESD:
A
ESD:
A
ADPE:
0
CRITL:
X
Hazmat (HMIC) Y

Indicates information is in the hazardous materials information resource system (hmirs).

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) A

No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Solicitation History DLA solicitations for NSN 6135-01-550-2518

Solicitation
Ends
Qty
AMSC
Buyer
PR
SMB
Solicitation:
SPE7L718T0366
End Date:
10/30/2017
Qty:
2 Ea
AMSC:
D
Buyer Code:
PLCL3
PR:
0071182862
SMB:
0%
Solicitation:
SPE7L715T6796
End Date:
09/14/2015
Qty:
4 Ea
AMSC:
D
Buyer Code:
PLCLC
PR:
0060252021
SMB:
100%