Serving our customers with quality and safety first.
23.500in. ⁓23-1/2"
5.250in.
19.000in.
shock proof
ups connectors, cable connectors, pinouts, ext.battery, remote control receptacle & mating plug, status plug, 6 nema 5-15P ouput receptacles, mounting options
1
powerstation ups, navy configuration N3 with internal isolation; 6130-01-491-8646
10000.0 feet
single single operating power rqmt and two single operating power rqmt and three single operating power rqmt
1.0 multiple power outputs w/identical ratings
115.0 ac pounds per hour wet single operating power rqmt
120.0 ac volts multiple power outputs w/identical ratings and 600.0 ac volts multiple power outputs w/identical ratings
46.0 hertz single operating power rqmt and 70.0 hertz single operating power rqmt
50.0 hertz multiple power outputs w/identical ratings and 60.0 hertz multiple power outputs w/identical ratings
+32.0/+126.0 deg fahrenheit
8 multiple power outputs w/identical ratings
switch multiple power outputs w/identical ratings
circuit overload protection device and filter and fuse and grounding and battery check switch and function switch and remote control
1000.0 ac VOLT-Ampere multiple power outputs w/identical ratings
single multiple power outputs w/identical ratings and two multiple power outputs w/identical ratings and three multiple power outputs w/identical ratings
full wave rectified sine wave ac multiple power outputs w/identical ratings and half wave rectified sine wave ac multiple power outputs w/identical ratings
constant voltage multiple power outputs w/identical ratings and limiting voltage multiple power outputs w/identical ratings
front panel multiple power outputs w/identical ratings and rear panel multiple power outputs w/identical ratings
8 multiple power outputs w/identical ratings
connector, receptacle multiple power outputs w/identical ratings and pin plug multiple power outputs w/identical ratings
12.0 ac amperes 1st operating power rqmt
pin plug single operating power rqmt
8 single operating power rqmt
external
air cooled
480.0
IEEE587 & UL1449; unix, HP-Ux, novell netware & windows nt
ups 1.0 kva
60.0
An item that provides continuous backup power to electronic devices in the event of a utility power dip or blackout. it generally contains a battery and a power inverter that provides the necessary backup power in the event of a loss of normal input utility power. it may also contain a power line filter or power line conditioning devices. excludes power supplies without standby power, electrical power inverers, and batteries.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.
No special marking.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.