NSN 6130-01-346-5836 NIIN 013465836 — Power Supply

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6130-01-346-5836
6130013465836
Description:
POWER SUPPLY
NSN Assigned:
08-OCT-91
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, --

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6130-01-346-5836 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

10.000in. ⁓10-1/64"

Overall Height ABKW:

3.500in.

Overall Width ABMK:

7.250in.

Environmental Protection ADZC:

fungus proof

End Item Identification AGAV:

an/USM-638; used on 8949102

Electrical Power Source Relationship AKWC:

operating

Input Phase ANPM:

single single operating power rqmt

Input Voltage Rating APNX:

207.0 ac pounds per hour dry 1st alternate operating power rqmt and 253.0 ac pounds per hour with retaining chain 1st alternate operating power RQMT103.5 ac pounds per hour dry 2nd alternate operating power rqmt and 126.5 ac pounds per hour with retaining chain 2nd alternate operating power rqmt

Output Voltage Rating APPA:

26.0 dc volts 1st power output and 30.0 dc volts 1st power OUTPUT14.65 dc volts 2nd power output and 15.55 dc volts 2nd power OUTPUT14.65 dc volts 3rd power output and 15.55 dc volts 3rd power OUTPUT12.22 dc volts 4th power output and 12.97 dc volts 4th power OUTPUT4.04 dc volts 5th power output and 5.25 dc volts 5th power OUTPUT-14.65 dc volts 6th power output and -15.55 dc volts 6th power output

Input Frequency Rating APTQ:

380.0 hertz 1st alternate operating power rqmt and 420.0 hertz 1st alternate operating power RQMT57.0 hertz 2nd alternate operating power rqmt and 63.0 hertz 2nd alternate operating power RQMT47.5 hertz 3rd alternate operating power rqmt and 52.5 hertz 3rd alternate operating power rqmt

Operating Ambient Temp Range AYNH:

-40.0/+71.0 deg celsius

Criticality Code Justification CRTL:

feat

Output Current Rating CWGH:

3.0 dc amperes 1st power OUTPUT4.0 dc amperes 2nd power OUTPUT2.5 dc amperes 3rd power OUTPUT5.0 dc amperes 4th power OUTPUT16.0 dc amperes 5th power OUTPUT-2.0 dc amperes 6th power output

Output Connection Quantity CWHF:

1 single power output

Output Connection Type CWHJ:

connector, receptacle single power output

Input Connection Type CWHQ:

connector, plug single operating power rqmt

Input Connection Quantity CWHT:

1 single operating power rqmt

Ventilation Design Type CWKG:

single fan

Power Supply Efficiency Line CWWY:

70.0

Special Features FEAT:

electrostatic sensitive device

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
SYS-3081
Cage Code:
61814
RNCC:
3
RNVC:
2
DAC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
8949111-01-1
Cage Code:
94117
RNCC:
5
RNVC:
2
DAC:
2
RNAAC:
MB
Status:
A
MSDS:
SADC:
Part Number:
8949111-01
Cage Code:
94117
RNCC:
5
RNVC:
2
DAC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
8949111
Cage Code:
98750
RNCC:
D
RNVC:
9
DAC:
2
RNAAC:
MB
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00740
FIIG:
A39900
Concept No.:
App. Key:
B
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "POWER SUPPLY"

A component which converts available alternating current or direct current electrical power into a form required to operate another component or set. The item may consist of a combination of an invertor, vibrator; vibrator, interrupter; vibrator, self-rectifying; invertor, power, static; with a transformer and rectifier(s) employing electron tubes, semiconductor diode or metallic (dry disc) type components, or the synchronized secondary contact(s) of a vibrator, self-rectifying; or may consist of electron tubes, semiconductor diode or metallic (dry disc) type rectifiers and capacitors in transformerless (alternating current-direct current type) circuits which may be of the voltage-multiplier type. The item may incorporate a filter, direct current power and provisions for regulation of input and/or output voltage. The item may have special input, output, control or other facilities for applications in specialized environments such as medical, dental or other operations. Excludes battery chargers and rotating machinery types of items, such as motor generators and dynamotors.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
14.5 X 12.5 X 8.5
Paclk Weight:
8.5000lbs
Item Weight:
6.7000lbs
Item Dim:
011500750045
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
F000003E44
SPI Rev.:
SPC Mkg:
17
LVL_A:
LVL_B:
LVL_C:
Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 17

Reusable container.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6130-01-346-5836 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
0
CRITL:
Y
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

ADPE 0

Represents items with no adp components

Criticality Y

The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restrictions or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
FLZ
SOS:
MMAC:
QC
MCC:
SOS:
NRP
SOS:
EW
MMAC:
MCC:
Source of Supply (SOS) FLZ

Warner-robins air logistics center 455 byron st robins afb, ga 31098-1860

Material Management (MMAC) QC

Electrical and electronic properties measuring and testing equipment

Special Material (SMIC) EW

Fleet electronic warfare support group

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.