NSN 6115-01-253-1024 NIIN 012531024 — Alternating Current Generator

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6115-01-253-1024
6115012531024
Description:
GENERATOR,ALTERNATING CURRENT
NSN Assigned:
11-APR-87
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6115-01-253-1024 Specification Set by the OEM (see RNCC code 3)

Overall Height AAJT:

111.000in.

Iii Overall Length AAJU:

108.380in.

Duty Cycle AKPS:

intermittent

Winding Type AXCP:

INDUCTION-Brush shifting

Mounting Method AXGY:

fixed base

Cooling Method BFMF:

WATER-Air cooled

Rotor Speed Rating In Rpm CWFX:

3600.0 single no load

Current Rating In Amps CWGL:

228.000 single input

Connection Type And Voltage Rating In Volts CWGQ:

450.0 line to neutral single input

Phase FAAZ:

three input

Frequency In Hertz FREQ:

60.0 input

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
783E585GR3
Cage Code:
01289
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
HD
Status:
A
MSDS:
SADC:
Part Number:
783E585GR3
Cage Code:
02989
RNCC:
5
RNVC:
2
DAC:
1
RNAAC:
HD
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00781
FIIG:
A271A0
Concept No.:
1
App. Key:
B
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "GENERATOR,ALTERNATING CURRENT"

A generator having a characteristic of current and voltage that is continually reversing in direction of flow at regular intervals. Does not include rotary inverters, motor-generators, generator sets, synchros, and frequency or phase changers. Excludes generator, tachometer.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
120.0 X 105.0 X 105.0
Paclk Weight:
lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
03
LVL_A:
F
LVL_B:
LVL_C:
LVL A Code (LVL_A) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 03

Method 50.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6115-01-253-1024 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.