NSN 6110-00-710-4324 NIIN 007104324 — Power Distribution Panel

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6110-00-710-4324
6110007104324
Description:
PANEL,POWER DISTRIBUTION
NSN Assigned:
01-JAN-63
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
1 EA
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6110-00-710-4324 Specification Set by the OEM (see RNCC code 3)

Overall Depth ABFY:

31.500in.

Wattage Rating In Watts ABJL:

50000.0

Overall Height ABKW:

74.000in.

Overall Width ABMK:

48.000in.

Mounting Method ADJH:

floor

Accessory Component Quantity AFHS:

6

Furnished Items AFJH:

circuit breaker, voltage regulator, lamp, indicator lights, fuse, fuse holder, relay, meter, switch, terminal board, connector, converter

End Item Identification AGAV:

an/FPS-20

Accessory Controlling Agency AKVY:

hwestinghouse electric corp, general electric co, dialight corp, bussmanmfg co, price electric co, weston electrical instrument corp, oak mfg co, micro switch division, scintilla division, bendix radio division

Accessory Identifying Number AKVZ:

48A3769G30 serial no. and 48A3769G26 serial no. and 32A7771G67 serial no. and CN-323/FPS-20 type no. and 31D3054 part no. and 80114-841 part no. and 1642-1 part no. and NE-45 part no. and 50a/rs part no. and hkl type no. and 1809-1 part no. and 3101216G1 part no. and 4380128G58 part no. and 1541 part no. and 1534 model no. and 46A8101G23 part no. and MS25103-1 type no. and 1AC1 part no. and +6422482GR12 part no. and 10-42220-4S part no. and 10-42232-17 part no. and L248892-1 part no.

Panel Material ANJG:

aluminum

Input Phase ANPM:

three

Inclosure Feature ANPZ:

fully inclosed

Output Frequency Rating ANSQ:

60 hertz

Panel Quantity APCA:

1

Electrical Input Quantity APNW:

1

Input Voltage Rating APNX:

208.0 ac volts

Input Neutral APNY:

provided

Electrical Output Quantity APNZ:

2

Output Voltage Rating APPA:

120.0 dc volts

Shock Absorbent Rating APPD:

will withstand 25 g shock test w/o regulators

Input Frequency In Hertz APPY:

60.000

Phase FAAZ:

three

Special Features FEAT:

SB-492A1FPS-20A

Reference Data And Literature RDAL:

fig 73-308, t.o. 31P6-2FPS20-4, technical manual, illustrated parts breakdwon, radar sets an/FPS-20, pg 193

Surface Treatment SURF:

enameled finish panel

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
R650174-3
Cage Code:
06845
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
SB492AFPS20A
Cage Code:
80058
RNCC:
5
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
02794
FIIG:
T122-G
Concept No.:
1
App. Key:
GA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "PANEL,POWER DISTRIBUTION"

A panel designed for connecting, disconnecting and protecting power line feeders and/or direct control of specific electric devices such as lights, motors, electronic equipment, etc. See also fuse box; switch box; distribution box; and panel, power bus, circuit breaker.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
9,999.9000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
19
LVL_A:
0
LVL_B:
F
LVL_C:
LVL B Code (LVL_B) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 19

Method 50 reusable container.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6110-00-710-4324 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
N
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality N

The item does not have a critical feature such as tolerance, fit restrictions or application. nuclear hardness properties have not been determined (not valid for input).

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
G69
SOS:
MMAC:
MCC:
Source of Supply (SOS) G69

Department of transportation federal aviation administration attn: coe aml-030 tsf bldg 215 po box 25082 oklahoma city, ok 73125-0082

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.