NSN 6110-00-646-4421 NIIN 006464421 — Power Bus Circuit Breaker Panel

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6110-00-646-4421
6110006464421
Description:
PANEL,POWER BUS,CIRCUIT BREAKER
NSN Assigned:
01-JAN-63
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, Coast Guard

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6110-00-646-4421 Specification Set by the OEM (see RNCC code 3)

General Characteristics Item Description TEXT:

12 circuits; 400 amp; 125vac; single phase; 50, 000 amp short circuit capacity; three 1X1/4 in. copper bus bars; designed for type ALB-1 and NLB-1 circuit breakers iaw MIL-C-17588; circuit breakers not included; aluminum enclosure; totally enclosed; o/a dim.; 28.50 in. h; 15.44 in. w; 6.50 in. deep; bulkhead mtg; six unthd mtg holes; 9/16 in. dia; rectangular pattern; 2 rows OF3 ea spaced 6 in. c to c; 13.44 in. cl to cl rows

Nondefinitive Spec/std Data ZZZT:

i type and 2 class

End Item End items to which 6110-00-646-4421 is a component of

  • AHN FIRE PUMPS
  • EYN STURGEON CLASS SSN (637)
  • F6N NUCLEAR SHIP ALTERATIONS
  • FBN SPRUANCE CLASS DD (963)
  • FGN CVN 68 CLASS REACTOR FILL AUXILIARY SYSTEM
  • HZN FORRESTAL CLASS CV
  • JAN NIMITZ CLASS CVN
  • JDN ARLEIGH BURKE CLASS DDG
  • JKN WASP CLASS LHD
  • XBN CVN NUCLEAR REACTOR BOUNDARY AREA

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
SYM 999.2
Cage Code:
81349
RNCC:
C
RNVC:
1
DAC:
3
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
SYM999.3
Cage Code:
81349
RNCC:
C
RNVC:
1
DAC:
3
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
M23928/1-03 TE
Cage Code:
81349
RNCC:
2
RNVC:
2
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
MIL-DTL-23928
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
E
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
700564-04-208
Cage Code:
58475
RNCC:
5
RNVC:
1
DAC:
5
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
H-505
Cage Code:
92772
RNCC:
C
RNVC:
1
DAC:
6
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
H-505-A
Cage Code:
92772
RNCC:
C
RNVC:
1
DAC:
6
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
MIL-P-23928
Cage Code:
81349
RNCC:
5
RNVC:
9
DAC:
4
RNAAC:
CX
Status:
A
MSDS:
SADC:
Part Number:
815-1197126REVASYM999-3
Cage Code:
80064
RNCC:
D
RNVC:
9
DAC:
1
RNAAC:
CX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
20479
FIIG:
A23900
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "PANEL,POWER BUS,CIRCUIT BREAKER"

An inclosure which includes two or more bus bar and is designed to mount and protect two or more circuit breaker, but does not include the circuit breakers. It may include a cover from which the actuators protrude and/or a trim with a door(s). For items which include combinations of different electrical devices such as switches, jacks, fuse holders, circuit breakers, terminal boards and the like, see distribution box. For items designed to mount but which do not include electrical devices, see junction box.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
24.5000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
O
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
E
LVL_B:
Q
LVL_C:
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) O

Options can be exercised as to specific method of preservation or dod approved packaging materials to be used. however, basic preservation method shall be retained, supplemental data shall be complied with, and unit package dimensions shall not be increased by more than one inch. equal or better protection shall be given the item and there shall be no increase in the package cost.

Special Markings Code (SPC_MKG) 00

No special marking.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6110-00-646-4421 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.