NSN 6110-00-186-2542 NIIN 001862542 — Power Distribution Panel

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
6110-00-186-2542
6110001862542
Description:
PANEL,POWER DISTRIBUTION
NSN Assigned:
09-MAR-73
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

6110-00-186-2542 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

72.000in. ⁓72-1/64"

Overall Height ABKW:

40.000in.

Overall Width ABMK:

36.000in.

Mounting Method ADJH:

floor

Panel Material ANJG:

aluminum

Input Phase ANPM:

three

Inclosure Feature ANPZ:

waterproof

Output Frequency Rating ANSQ:

60 hertz

Panel Quantity APCA:

1

Electrical Input Quantity APNW:

1

Input Voltage Rating APNX:

480.0 ac pounds per hour with retaining chain

Electrical Output Quantity APNZ:

7

Output Voltage Rating APPA:

120.0 ac volts and 208.0 ac volts

Input Frequency In Hertz APPY:

60.0

Phase FAAZ:

three

Special Features FEAT:

portable assembled unit, 650 lb max wt, liftable by fork lift, consists of 5 480v circuits of 2 3-pole 225 amp circuit breakers w/lugs only, 1 3-pole 30 amp circuit breaker feeding the input side of a 15kva 480 delta, 208/120v, 3 phase, dry transformer, 1 2-pole 100 amp and 2 2-pole 50 amp circuit breakers w/lugs only to be connected on the 208/120v side of the transformer, 2 3-pole 30 amp circuit breakers protecting two receptacles, nema configuration L21-30R and 14 1-pole 20 amp circuit breakers of the ground fault type, ul approved, protecting fourteen receptacles, nema configurations L5-20R, ground lug to accommodate a no. 1 or 2 awg copper wire, all circuit breakers to conform to fed spec W-C-375

Nondefinitive Spec/std Data ZZZT:

ii type and 1 class

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
6002607
Cage Code:
80091
RNCC:
3
RNVC:
2
DAC:
1
RNAAC:
JN
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
02794
FIIG:
T122-G
Concept No.:
1
App. Key:
GA
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "PANEL,POWER DISTRIBUTION"

A panel designed for connecting, disconnecting and protecting power line feeders and/or direct control of specific electric devices such as lights, motors, electronic equipment, etc. See also fuse box; switch box; distribution box; and panel, power bus, circuit breaker.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
99
LVL_A:
E
LVL_B:
Q
LVL_C:
Q
LVL A Code (LVL_A) E

Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.

LVL B Code (LVL_B) Q

Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

6110-00-186-2542 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
R41
SOS:
MMAC:
MCC:
Source of Supply (SOS) R41

Commanding officer naval construction battalion center civil engineer support office code 15324 port hueneme, california 93043-5000

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.