NSN 5895-01-510-3399 NIIN 015103399 — Radio Frequency Switch-amplifier

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5895-01-510-3399
5895015103399
Description:
SWITCH-AMPLIFIER,RADIO FREQUENCY
NSN Assigned:
17-JUL-03
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
1 EA
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5895-01-510-3399 Specification Set by the OEM (see RNCC code 3)

Overall Length ABHP:

4.500in. ⁓4-1/2"

Overall Height ABKW:

0.655in.

Overall Width ABMK:

1.700in.

Average Life Measurement AFSU:

not rated

End Item Identification AGAV:

an/ALQ-131 (v)

Basic Shape Style AGTA:

rectangular or square

Inclosure Type AKNA:

encased

Operating Control Method ALBM:

automatic

Installation Design AMQY:

mechanical

Control Type AQZF:

remote

Circuit Construction Type BHSX:

solid state

Criticality Code Justification CRTL:

feat

Special Features FEAT:

electrostatic discharge sensitive

Special Markings MARK:

esd symbol

Reference Number Differentiating Characteristics ZZZY:

as differentiated by repair parts

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
312352-702
Cage Code:
81413
RNCC:
1
RNVC:
3
DAC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
CSA-925318M
Cage Code:
2J873
RNCC:
3
RNVC:
3
DAC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
CSA-925318M
Cage Code:
2J873
RNCC:
3
RNVC:
3
DAC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
312352-702
Cage Code:
81413
RNCC:
1
RNVC:
3
DAC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
CSA-925318M
Cage Code:
2J873
RNCC:
3
RNVC:
3
DAC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
312352-702
Cage Code:
81413
RNCC:
1
RNVC:
3
DAC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
48691
FIIG:
A32200
Concept No.:
App. Key:
A
Cond. Code:
1
Status:
A
BASIC SHAPE STYLE RECTANGULAR OR SQUARE style nsn 5895-01-510-3399

Definition Definition of approved item name (AIN): "SWITCH-AMPLIFIER,RADIO FREQUENCY"

An item having the dual function of a radio frequency amplifier and a radio frequency switch. The switching function may be manual, electromechanical or by means of an arrangement of semiconductors and passive circuit devices.

Related NSNs

Related NSN
Service
OOU
JTC
Phrase
Related NSN:
5895-01-511-4600
Service Code:
OOU:
JTC:
Phrase Code:
E
Phrase Code E

Indicates the item represented by the nsn in the input/output header is replaced by the interchangeable preferred item represented by the nsn in the segment h (stocks will be used until exhausted). Must be used in combination with phrase code g addressed to the nsn in the segment h.

  Relationship Codes

OOU: Order of Use. Three position alpha code denoting the interchangeability and substitutability (I&S) relationship of a national stock number within a service/agency I&S family.

JTC: Jump to Code. Three position alpha code that denotes an exception to the normal sequence to be followed in the attrition of items within an interchangeability and substitutability (I&S) family.

Phrase Code: A one position code assigned to a phrase used in the management data list to denote changes and/or relationships between national stock numbers and reference data.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
0.0000lbs
Item Weight:
0.0000lbs
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
M
SPI No.:
SPI Rev.:
SPC Mkg:
39
LVL_A:
LVL_B:
LVL_C:
Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 39

Esd sensitive electronic device requirements of mil-std-129 apply.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5895-01-510-3399 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
B
ESD:
B
ADPE:
0
CRITL:
Y
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Electrostatic Discharge (ESD) B

Represents items with esd sensitivity.

ADPE 0

Represents items with no adp components

Criticality Y

The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restrictions or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
FLZ
SOS:
MMAC:
EW
MCC:
Source of Supply (SOS) FLZ

Warner-robins air logistics center 455 byron st robins afb, ga 31098-1860

Material Management (MMAC) EW

Airborne electronic warfare equipment

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.