stable SELF-Contained freq. synthesizer for use with low freq. transmitter; all freq. derived form internal 1 mhz oscillator; optional external freq. standard; output adjustable freq. 2.030 mhz to 2.150 mhz in 10 hz steps; two fixed output freq. 100 khz and 1 mhz; freq. selection by pushbuttons or switches; output harmonic freqs. at least 40 db below the fundamental freq; NON-Harmonically spurious freq. at least 70 db below fundamental; signal to phase noise ratio greater then 60 db over 12 khz band; signal to am noise ratio greater then 70 db over 12 khz band; enclosure construction designed to minimize interference; ac power reqmts. 115/230 v ac porm 10 percent single phase, 50/60 hz porm 5 percent; standard 19.000 in. relay rack; chasis equipped with chasis slides; operating temp. 0.0 to 50.0 deg. c; storage temp. M40.0 to 75.0 deg. c; mean time between failures 5000 hours.
An item with the combined functions of a frequency divider and a frequency multiplier. It provides a multiplicity of discrete output signals harmonically related to a standard source frequency, that may be utilized in radio receivers, transmitters, musical instruments, test equipment, density of rapidly selectable individual communication frequency bandwidth. See also generator, reference signal. Excludes frequency divider; frequency multiplier; and keyboard instrument, electronic.
Packing shall be accomplished to meet the performance test requirements of astm-d4169, distribution cycle 18, assurance level 1.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.
Method 50.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.
Navicp-erp 700 robbins avenue philadelphia, pa 19111-5099
SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.
SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.
MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.
MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category
IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.