NSN 5895-00-689-6079 NIIN 006896079 — Control-monitor

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
5895-00-689-6079
5895006896079
Description:
CONTROL-MONITOR
NSN Assigned:
01-JAN-63
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

5895-00-689-6079 Specification Set by the OEM (see RNCC code 3)

Dc Voltage Rating ACYR:

28.0 volts

Joint Electronics Type Designation System Item Name AKWA:

CONTROL-Monitor

Joint Electronics Type Designation System Item Type Number AKWB:

C-4835/mpn

Usage Design ALCD:

controls headset audio level controls loudspeaker audio level controls selection of intercom circuits

Internal Battery Accommodation ALSF:

not included

Input Signal Quantity AMMD:

25

Monitoring Method AWMS:

visual

Input Signal Frequency Rating AWMT:

0.25 kilohertz and 4.00 kilohertz

Input Signal Type AWNS:

af signals

Fsc Application Data ZZZV:

mod kit, landing control central

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
114233
Cage Code:
24930
RNCC:
3
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
C4835MPN
Cage Code:
80058
RNCC:
5
RNVC:
2
DAC:
X
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
00906
FIIG:
T121-A
Concept No.:
App. Key:
AB
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "CONTROL-MONITOR"

A component which performs the dual function of examining part of the output from other components or sets and regulates the mode of operation of another set. The control is not essential to the end use or operation of the component or set. See also control-indicator.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
5,600.0000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
A
SPI No.:
F006896079
SPI Rev.:
SPC Mkg:
ZZ
LVL_A:
LVL_B:
F
LVL_C:
LVL B Code (LVL_B) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) A

Packaging is in accordance with a procedural specification or a special packaging instruction (spi). the appropriate specification number will be shown in the clear in the supplemental data area.

Special Markings Code (SPC_MKG) ZZ

Special requirements.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

5895-00-689-6079 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.