Serving our customers with quality and safety first.
15.770in. ⁓15-25/32"
2.100in.
6.120in.
807l
5.500 pounds
cinput bandwidth 10 mhz min; sweep width 100 khz - 10 mhz; sweep rate 30 hz; resolution 10 khz; rf gain control range 80 db min; image rejection 60 db min; power reqmts +15 vdc at 740 ma and -15 vdc at 165 ma supplied from 2861-h accessory housing; temp range oper 0 to +50 deg c, storage -55 to +65 deg c; altitude oper to 10, 000 ft, storage to 50, 000 ft; rel humidity to 95 percent NON-Condensing; input impedance 50 ohms; operating frequency 160.0 mhz
A single component designed to amplify and separate into individual signals, meter and/or instrument data, into the form of electrical pulses which may be recorded by a telemetric data recorder.
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Item does not contain precious metal.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.