Serving our customers with quality and safety first.
1.285in. ⁓1-19/64"
flush (flat) countersunk (included angle - less than 135 deg w or w/o chamfer)
0.2890in. and 0.2910in.
threaded SELF-Plugging shank w/sleeve
0.453in. and 0.503in.
threaded stem
0.532in. and 0.594in.
3650 pounds per square inch
48.0 rockwell c stem and 53.0 rockwell c stem
11800 double pounds per square inch
99.0 degrees and 101.0 degrees
steel comp H11 stem
AMS5667 assn std single material response sleeve or AMS5582 assn std single material response sleeve or AMS5731 assn std single material response sleeve or AMS5732 assn std 4th material response sleeve or AMS5737 assn std 5th material response sleeve
cadmium stem and chromate stem
NAS672 assn std 1st treatment response stem and QQ-P-416 fed spec 2nd treatment response stem
An item consisting of two or more of the following components: stem, rivet body, sleeve, expander, bolt, and collar. It is a headed fastening device with the shank designed to be expanded by means of a separate or integral stem or mandrel, or bolt and expander. It is designed to be installed or expanded from one side only. Excludes nut, blind assembly.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Precious metal content is unknown
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.