Serving our customers with quality and safety first.
F112-WR-100 engine
ovoltage 110 vac; PUMP-Explosive proof, 2 hp, 0-20 gal/min.; GAGES-Illuminated, 0-500 psi; holding tank CAP-25 gallons; filter SYSTEM-0-100 micron; cabinet outer SHELL-Plate aluminum; dim:7 ft.lg, 3 ft.w, 6 ft.h; weight 450 lbs
uesed during depot level maintenance of the F112-WR-100 turbofan engine to dynamically inspect/test the lubrication and scavenge lube pump assy; the test set stand will drive the lube pump and supply oil or calibration fluid, shaft rpm, fluid delivery rate, and required instrumentation for speed, flow, temperature, and pressure indications
88-10-01
A group of items, such as signal generators, voltmeters, test adapters, flowmeters, calibrators, gyro simulators, gages, power supplies, thermocouplers, and other necessary equipment for testing components of a guided missile system. It does not contain hand tools or spare replacements. See also test equipment, guided missile remote control system.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.