NSN 4920-01-423-8487 NIIN 014238487 — Hydraulic System Comp Test Stand

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
4920-01-423-8487
4920014238487
Description:
TEST STAND,HYDRAULIC SYSTEM COMP
NSN Assigned:
11-JAN-96
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

4920-01-423-8487 Specification Set by the OEM (see RNCC code 3)

Hydraulic Fluid Flow Rate AAYJ:

5.0 gallons per minute

Current Type ACDC:

ac

Usage Design ALBY:

aircraft hydraulic system

Installation Design AMQY:

fixed

Power Source ATJK:

electric motor

Accumulator AYJM:

not included

Pressure Rating BGST:

4000.0 pounds per square inch and 6000.0 pounds per square inch

Engine Driven Hydraulic Pump Testing Design Feature CGYK:

not included

Pressure Manifold Subcircuit CGYM:

not included

Filtering System CHGQ:

not included

Pressure/suction Hose CHGR:

not included

Part Name Assigned By Controlling Agency CXCY:

hydraulic test bench

Voltage In Volts ELEC:

115.0

Phase FAAZ:

single

Special Features FEAT:

dual system, manually operated, stationary test bench with a stainless steel cabinet; uses depot 4000 psi AND6000 psi hydraulic manifolds for hydraulic pressure and flow; includes all necessary hyrdaulic filters, regulators, pressure gauges, flow meters, reliefvalves and control valves; all pressure gauges and flow meters have analog and digital readouts; includes BUILT-Inelectrical dc power supply and duel servo controlers with lvt feedback; hydraulic fluid per MIL-H-83282; fluid temp +50 to 275 deg f; flow vs pressure: 5 gpm at 6000 psi, 30 gpm at 4000 psi, 60 gpm at 500 psi; height 72in., width 120in., depth 49in.

Frequency In Hertz FREQ:

60.0

Functional Description FTLD:

used to functionally test all C-17A hyrdaulic lru's except pumps

Reference Data And Literature RDAL:

serd number 450398

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
17G450398-1
Cage Code:
88277
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
17G450398-1
Cage Code:
88277
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
17G450398-1
Cage Code:
88277
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
17G450398-1
Cage Code:
88277
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
17G450398-1
Cage Code:
88277
RNCC:
3
RNVC:
2
DAC:
4
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
11017
FIIG:
T361-E
Concept No.:
App. Key:
EA
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "TEST STAND,HYDRAULIC SYSTEM COMP"

A cabinetlike item usually with a front work area and consisting of the necessary instrumentation, integral hydraulic system and component mounting facilities. Designed to provide the hydraulic pressure for testing and/or calibrating hydraulic system components, such as valves, actuating cylinders, pressure regulators, accumulators, hose lines, hand and/or engine driven pumps and the like. May include facilities for filling and checking hydraulic systems for leakage and performance. See also pumping unit, hydraulic.

4920-01-423-8487 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.