Serving our customers with quality and safety first.
allison TF41 series engines
fuel control test stand assy
tests fuel control systems
fuel control test stand assy
test stand assy consists of (all measurements are inin.) CONSOLE-140X120X88; variable speed drive remote CABINET-80X24X72; air COMPRESSOR-60X24X72; vacuum PUMP-48X24X48; reduced voltage motor STARTER-24X20X72; power REQUIREMENTS-220/440 volts, 3 phase, 60 hz 235kva; WATER-60 gpm at 30-40 psig and 65degrees f max; shop air (instrument quality) 5 scfm free air at 90-110 psig
the test stand assy is a SELF-Contained unit which incorporates its own hydraulic system to supply test fluid to the unit under test at specified pressures and flows
t.o.33D4-6-343-1
the stand as shipped from the factory is connected for 440 volt service
A group of items containing a console and/or perpheral equipment specifically designed to provide appropriate instrumentation and data acquisition/control logic for testing of components of an aircraft fuel system.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.