Serving our customers with quality and safety first.
poppet
400.0 deg fahrenheit single response
beverage dispensing equipment; gas pilot plants; petrolchemical test labs; off shore oil platform heating lines; pharmaceutical sterilization and packaging systems
unthreaded internal tube 2nd end
482.0 bar single response
relief valve
seal material viton, body 316 stainless steel; 1/4" male npt x 1/4" female npt; top to orifice center 7.47cm, orifice center to bottom 3.66cm, bottom center to orifice edge 2.54cm; cracking pressure 150-2500Psig or 10-172 bar; spring range in psig 4001-5000 (276-345 bar)
steel comp 316 body
WATER-OIL-Gas single response
A valve designed to automatically release excessive pressures. It is actuated by static pressure upstream of the valve and is used as a safety valve or relief valve, and may be set to close at a predetermined pressure. It is not designed for regulation of continuously fluctuating loads. It may be inline or cartridge (manifold) design. Excludes valve (1), relief, pressure and temperature.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
No known electrostatic discharge (esd) or electromagnetic interference (emi) sensitivity.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.