Serving our customers with quality and safety first.
RIGHT-Hand all ends
piston
35.0 gallons per minute
ships control system onboard 270 ft wmec c.g. vessels
G9 plain, optional end (pipe) all ends
automatic
threaded internal pipe all ends
200.0 pounds per square inch single response
0.750in. all ends ⁓3/4"
steel body
hydraulic fluid, petroleum base single response
nptf all ends
A valve designed to automatically release excessive pressures. It is actuated by static pressure upstream of the valve and is used as a safety valve or relief valve, and may be set to close at a predetermined pressure. It is not designed for regulation of continuously fluctuating loads. It may be inline or cartridge (manifold) design. Excludes valve (1), relief, pressure and temperature.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.