NSN 4820-00-422-1142 NIIN 004221142 — Gate Valve

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
4820-00-422-1142
4820004221142
Description:
VALVE,GATE
NSN Assigned:
16-DEC-70
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

4820-00-422-1142 Specification Set by the OEM (see RNCC code 3)

Bonnet Type ADSR:

packing retaining

Valve Operation Method AQLR:

manual

Connection Type AWLS:

threaded internal pipe

Valve Size CCFG:

3.000in.

Maximum Operating Pressure And Media For Which Designed CQCJ:

125.0 pounds per square inch steam and 20.0 pounds per square inch WATER-OIL-Gas

Nominal Thread Size CQJX:

3.000in. ⁓3-1/64"

Stem Type CRKP:

nonrising

Inlet Relationship With Outlet CYBZ:

identical

Special Features FEAT:

double disc

Material MATT:

steel stem

Material Document And Classification MDCL:

astm B-62 assn std single material response disk

Thread Series Designator THSD:

npt

Furnished Items And Quantity TMQY:

1 lever

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
362-3IN
Cage Code:
48422
RNCC:
3
RNVC:
2
DAC:
3
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
P901-U-3IN
Cage Code:
76364
RNCC:
3
RNVC:
2
DAC:
3
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
56116042
Cage Code:
37562
RNCC:
5
RNVC:
2
DAC:
5
RNAAC:
CT
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
05482
FIIG:
A500A0
Concept No.:
1
App. Key:
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "VALVE,GATE"

A valve having a flat or tapered disk (gate) which moves transversely to the axis of flow by rotating or sliding movements of the stem to open or close the orifice. It may also contain an oval or rectangular shaped slide which may be manually, motor, or pressure operated through the means of an arm or arm assembly. The body flange may be designed to accommodate tube type connectors. It may or may not contain thermal relief features. Includes valve (gate) specifically designed for the control of fluid systems in aircraft or missiles.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
--
Paclk Weight:
4.1000lbs
Item Weight:
--
Item Dim:
--
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
G
LVL_B:
R
LVL_C:
6

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

4820-00-422-1142 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.