NSN 4810-01-172-1184 NIIN 011721184 — Electro-mechanical Rota Actuator

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
4810-01-172-1184
4810011721184
Description:
ACTUATOR,ELECTRO-MECHANICAL,ROTA
NSN Assigned:
16-FEB-84
DEMIL:
NO
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

4810-01-172-1184 Specification Set by the OEM (see RNCC code 3)

Terminal Type AARB:

socket

Current Type ACDC:

dc

Shaft Rotation Direction AKCT:

counterclockwise

Drive Type AKCV:

direct

Duty Cycle AKPS:

continuous

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
DYNC11006-224
Cage Code:
65149
RNCC:
3
RNVC:
2
DAC:
3
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
DYNC1106-223-0-12
Cage Code:
65149
RNCC:
5
RNVC:
9
DAC:
3
RNAAC:
CT
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
11006
FIIG:
A30500
Concept No.:
App. Key:
B
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "ACTUATOR,ELECTRO-MECHANICAL,ROTA"

A self-contained power transmitting device designed to convert electrical energy into controlled mechanical force, in the form of torque (rotational mechanical movement). Comprised of an electric motor(s), gear box(es), limit switch(es), and such accessories as required for the specific moving and positioning of other components. Excludes hydraulic and pneumatic cylinders and screwjacks.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
8.0 X 6.4 X 7.0
Paclk Weight:
11.8000lbs
Item Weight:
--
Item Dim:
007500500050
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
--
OPI:
SPI No.:
SPI Rev.:
SPC Mkg:
00
LVL_A:
Q
LVL_B:
H
LVL_C:
U

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

4810-01-172-1184 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
0
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

ADPE 0

Represents items with no adp components

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.