4810008668218
Description:
VALVE,LINEAR,DIRECTIONAL CONTROL
NSN Assigned:
01-JAN-60
DEMIL:
 DEMIL
Shelf Life:
N/A
UOM:
--
Using Services:
--

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

4810-00-866-8218 Specification Set by the OEM (see RNCC code 3)

Thread Class AAJD:

3b

End Connection Quantity ADQZ:

4

End Item Identification AGAV:

u/o C-141 acft; 9H8-4-163-3, 1C-141B-4-3

Current Rating In Amps AMPS:

0.7

Valve Operation Method AQLR:

solenoid

Connection Type AWLS:

threaded internal boss

Maximum Operating Pressure And Media For Which Designed CQCJ:

3000.0 pounds per square inch hydraulic fluid, petroleum base

Nominal Thread Size CQJX:

0.250in. ⁓1/4"

Iii Body Material CQRG:

aluminum alloy

Criticality Code Justification CRTL:

feat and agav

Maximum Operating Temp And Media For Which Designed CRWH:

160.0 deg fahrenheit hydraulic fluid, petroleum base

Voltage In Volts And Current Type CSBH:

17.0 dc and 28.0 dc

Flow Pattern Quantity CYGY:

4

Spool Position Quantity CYGZ:

1

Spool Quantity CYHB:

1

Special Features FEAT:

manufacturers suggested name is VALVE-Hydraulic, solenoid operated, 4-way, 3 position, 1/4 inch ports; valve ports connections 1/4 inch tube size per AND10050-4 (MS33649) ; wt 1.44 lbs; pressures: operating press and cyl ports 3000 psig, ret port 1500 psig; proof press and cyl ports 4500 psig, ret port 2250 psig; burst press and cyl ports 7500 psig, ret port 3750 psig

Thread Series Designator THSD:

unf

Reference Number Differentiating Characteristics ZZZY:

as differentiated by source control drawing

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
3H90044-101
Cage Code:
98897
RNCC:
1
RNVC:
3
DAC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
5C5617
Cage Code:
70236
RNCC:
3
RNVC:
3
DAC:
5
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
5C5617
Cage Code:
99215
RNCC:
5
RNVC:
9
DAC:
2
RNAAC:
XX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
61929
FIIG:
A506H0
Concept No.:
1
App. Key:
Cond. Code:
2
Status:
A

Definition Definition of approved item name (AIN): "VALVE,LINEAR,DIRECTIONAL CONTROL"

A manually or power operated valve having three or more ports. The direction of the flow through the various ports is controlled by either one or more reciprocating slide(s) or spool(s) with recess areas which mate with ports in an integral or replaceable ported sleeve, or one or more poppet(s). It is designed to change the direction of fluid flow from one valve port to another. An off (no flow) position is not a flow pattern. The valve is designed to actuate various components of a fluid system. A power operated valve may have a manual override. For items which stop, start, or change the flow of fluid, see: valve, solenoid. Excludes valve, plug. See also servovalve, hydraulic; body section, working, linear directional control valve; and valve assembly.

Packaging & Dimensions Packaging instructions, special markings, and approx. weight/dims

Pack Size
Pack Weight
Item Weight
Item Dim.
Pack Size:
10.5 X 10.5 X 12.5
Paclk Weight:
2.3000lbs
Item Weight:
1.0000lbs
Item Dim:
004800330030
Container
OPI
SPI No.
SPI Rev.
SPC Mkg.
LVL A
LVL B
LVL C
Container:
4294967295
OPI:
M
SPI No.:
F000003XA3
SPI Rev.:
SPC Mkg:
17
LVL_A:
0
LVL_B:
F
LVL_C:
0
LVL B Code (LVL_B) F

Packing is not required. the unit container shall also serve as the shipping container. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.

Procedure Indicator Code (OPI) M

All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.

Special Markings Code (SPC_MKG) 17

Reusable container.

  Packaging Codes

OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.

SPI No.: Special packaging instructions number.

LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.

SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.

4810-00-866-8218 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
0
CRITL:
Y
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

ADPE 0

Represents items with no adp components

Criticality Y

The item does not have a nuclear hardened feature but does have other critical feature(s) such as tolerance, fit restrictions or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.