air
round 2nd end
flange 1st end
4.750in. all ends
4.094in.
0.156in. all ends
plain 2nd end
0.125in. all ends
4.000in. all ends
end 1 has gasket ring undercut 4.375 inch od by 4.000 inch id by 0.094 inch dp.end 2 has gasket ring undercut 4.062 inch od by 0.125 inch dp cut to the 3.875 inch bore id.o/a dim 11.12 inch lg by 9.00 inch w by 4.50 inch h.one external thd flared tube fitting 7/16-20Unf and one internal thd dbl compression fitting 7/16-2Ounf provided for hydraulic hose attachment.solenoid installed p/n 311473-4-99193.two each compression ring gaskets furnished, 4.37 inch od by 4.03 inch id by 0.156 inch thk
steel stem
passivate
99193-109382-17-1 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
A valve that controls flow by a circular disk, or a pair of semicircular disks, attached to a common spindle or lever turning on a diametral axis.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Precious metal content is unknown
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.