Serving our customers with quality and safety first.
3a all ends
225.0 deg fahrenheit 1st response
flared (tube) all ends
2.297in. 4th end
threaded external tube all ends
12 all ends
1500.0 pounds per square inch single response
1.875in. all ends ⁓1-7/8"
37.0 degrees all ends
1.500in. all ends
aluminum alloy 2014 or aluminum alloy 2024
QQ-A-225/4 fed spec 1st material response or QQ-A-225/6, temper T6 or T851 fed spec 2nd material response
oxygen, gaseous 2nd response
anodize
MIL-A-8625, ty 2, cl 2, light blue mil spec single treatment response
unj all ends
88044-AN827 government standard and 81343-AS4841 professional/industrial association standard
A fitting having four branches in the same plane whose axes form right angles. The connections have machine threads (straight threads other than pipe or hose series) designed to accommodate a tube or are unthreaded and designed to accommodate a tube. It is designed to be used as a junction at the intersection of tubing and/or tube fittings. It may have side inlet(s).
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with applicable specification for shipping container.
Packing shall be accomplished in accordance with table c.ii for the packing level specified. closure, sealing and reinforcement shall be in accordance with the appropriate shipping container specification.
All packaging data is mandatory for compliance and no substitutions are permitted. fast packs should be included in this category.
No special marking.
OPI: Optional Procedure Indicator Code. A one position alpha code that indicates the allowable deviations from the prescribed requirements.
SPI No.: Special packaging instructions number.
LVL A/B/C: Indicates the type of shipping container required for level A, B, or C maximum packing protection.
SPC Mkg: A two position code that identifies the special markings applied to the container, which is part of the total pack to protect the contained item during preservation, packing, storage, transit and removal from the pack.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Precious metal content is unknown
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.