Space And Water Heating Equipment FSG 45 — FSC 4520

NSN
NIIN
Name
Details
01-503-4290
Damper Control Quadrant
Used on seawolf class ssn; plo acoustic. 7.670" overall length 2.740" overall width 120.0 ac voltage in volts and current type actuator, on/off, 35 in-lb torque has 3 ft, 18 ga appliance cable, 0.500 inch conduit connector; electronic overload protection throughout 0-95 deg rotation; visual position indicator, 0-90 deg; true mechanical spring return failsafe; easy to adjust mechanical stop to limit damper rotation zinc surface treated
01-503-5658
Electrical Nonim Heating Element
Element heater mtl. is kapton, 20 - 24 guage 4 inch leads, .55 x 15" long w/ psa psa backing
01-503-5921
Electrical Nonim Heating Element
Used on radar threat emiter an/mst-t1; m3p reu-m. 17.880" overall length 120.0 ac single voltage voltage in volts and current type heater strip; finned strip heater material: 304 stainless steel; mounting slot size: standard 5/16 inch x 1/2 inch; max. amperage: 22 amps unf screw thread series
01-503-5928
Ventilation Duct Terminal
Used on damper assembly. 16.000" overall length 8.000" overall width auxilliary exhaust de-smoke terminal with solenoid operated damper specify NSD61-height (10) -width (8) -length (16) -control location (see supp) -material-voltage (e.g., NSD61-10-8-16-rr-ss-115) straight
01-503-5971
Water Electric Heater
460.0 ac/dc voltage in volts and current type 51 amps; 1 inch bronze relief valve: 100 psig/210 deg f; thermostatic switch range: 90-180 deg f
01-503-5981
Electrical Nonim Heating Element
Used on dehydrator, unit 4440-01-502-9798. 115.0 ac 3rd voltage voltage in volts and current type heater assy. pressure 450 psi, mat is 300 series steel stl, resistance limits 23.8 - 27.8 ohms
01-503-6159
Water Electric Heater
460.0 ac/dc voltage in volts and current type 103amps; 1 inch bronze relief valve: 110 psig/210 deg f; thermostatic switch range: 90-180 deg f
01-503-6344
Electrical Nonim Heating Element
Used on heater vent; military electric duct heater - size 34eh, type l. 58.125" overall length 440.0 ac single voltage voltage in volts and current type finned tubular heating element high shock resistance
01-503-6394
Electrical Nonim Heating Element
01-503-6626
Electrical Immer Heating Element
0.875" hole diameter 31.394" overall length 440.0 ac single voltage voltage in volts and current type immersion heater, flanged, reduction gear lo setting tank heater, (model tms-2418E4xxi) 440v, 18kw, 1-3ph, 13wpsi capacity:heats 800 gallons of 2190 tlp from 38 deg c to 79 deg c in 5 hours; high shock resistance unc mounting facility thread series
01-503-6679
Electrical Immer Heating Element
01-503-6986
Immersion Liquid Fuel Fir Heater
01-503-7586
Electrical Immer Heating Element
Used on seawolf class ssn; plo acoustic. 0.245" hole diameter 50.875" overall length 0.563" outside diameter 440.0 ac single voltage voltage in volts and current type special tube-in-tube design 9/16 diameter heater for marlo coil mounting flange made of 16ga, 304sst, tackwelded to tube; terminals are 18 ga. exane leadwire with 0.875 inch long silicone rubber sleeving at flange; cavity is sealed with clear epoxy
01-503-8158
Electrical Nonim Heating Element
01-503-8784
Electrical Immer Heating Element
Used on seawolf class ssn; plo acoustic. 53.500" overall length 440.0 ac single voltage voltage in volts and current type heater, "u" bend, 500w, 440v unf stud thread series
01-504-0529
Electrical Immer Heating Element
0.875" hole diameter 44.000" overall length 440.0 ac single voltage voltage in volts and current type immersion heater, flanged, main propulsion diesel engine lo sump tank heaterk tms-1516E4xx, 440v, 16kw, 1-3ph, 11wpsi designed to heat 1800 gallons or 2190 tep from 4 deg c to 38 deg c in 10.5 hours; terminals are hermetically sealed
01-504-1442
Space Heater
Used on b-2 acft/support equipment.
01-504-1743
Air Conditioning-heating Pipe
Used on kdc-10 aircraft. pipe assembly-brazed
01-504-2020
Electrical Immer Heating Element
Used on heater, water. 240.0 ac single voltage voltage in volts and current type single-phase immersion 3.5 kw element has two terminals; element is brazed into a brass flange; assembly is fastened to corresponding tank flange using a gasket
01-504-2033
Water Electric Heater
Used on heater, water. 21.000" overall length 15.000" overall width 240.0 ac voltage in volts and current type model A67s, 6 gallon capacity, 7 kw, 240 volt, single phase, 60 hz with 2 immersion 3.5 kw elements ch-fo-354; used for 180 degree f sanitizing rinse water
01-504-2104
Electrical Nonim Heating Element
Used on space heater; air heater - blower, surface mounting, "rsfm" marine. 10.680" overall length 254.0 ac single voltage voltage in volts and current type finned tubular element assembly rsfm marine heater fins have 0.844 outer diameter with 5.5-6.5 fins per inch; terminal ends are 1.375-1.500" apart
01-504-3033
Duct Type Portable Heater
01-504-3431
Electrical Nonim Heating Element
01-504-3987
Electrical Nonim Heating Element
Used on thaw cabinet: thw50-2m-sn-mlr. 115.0 ac single voltage voltage in volts and current type mullion heater 4 watts per foot
01-504-4069
Duct Type Stationary Heater
Used on safire imager. heater-atu
01-504-8269
Air Conditioning-heating Adapter
Used on 5999-01-498-0566: interface device adapter assy; 0preader bar. 7.240" overall length 5.100" overall width inlet air hood made from 3.000 x 0.125 inch wall tube aluminum alloy, 6061-T6 per qq-a-25-/8 chromium surface treated nonadjustable
01-504-8511
Electrical Nonim Heating Element
Used on virginia class submarine, ssn-774; thaw cabinet. 115.0 ac single voltage voltage in volts and current type tubular heater
01-504-9528
Air Register
Used on los angeles class ssn (688); ventilation - crews mess & dry provisions; module control. 6.000" overall length 6.000" overall width diffuser, rectangular, t-14 ventilation
01-504-9905
Air Register
Used on los angeles class ssn (688); ventilation - chief petty officers quarters & storekeepers office; module control. 12.000" overall length 9.000" overall width diffuser, rectangular, t-09
01-504-9944
Air Register
Used on los angeles class ssn (688); ventilation - chief petty officers quarters & storekeepers office; module control. 6.000" overall length 6.000" overall width diffuser, rectangular, t-30
01-504-9992
Air Register
Used on los angeles class ssn (688); ventilation - chief petty officers quarters & storekeepers office; control module. 6.000" overall length 6.000" overall width diffuser, rectangular, t-31
01-504-9997
Air Register
Used on los angeles class ssn (688); ventilation - chief petty officers quarters & storekeepers office; control module. 9.000" overall length 9.000" overall width diffuser, rectangular, t-11
01-505-0000
Air Register
Used on los angeles class ssn (688); ventilation - chief petty officers quarters & storekeepers office; control module. 9.000" overall length 9.000" overall width diffuser, rectangular, t-08
01-505-0009
Air Register
Used on los angeles class ssn (688); ventilation - crews living - upper level; module control. 12.000" overall length 9.000" overall width diffuser, rectangular
01-505-0140
Air Register
Used on los angeles class ssn (688); ventilation - crews living & transformer space; module control. 9.000" overall length 6.000" overall width diffuser, rectangular, t-42
01-505-0149
Air Register
Used on los angeles class ssn (688); ventilation - crews mess & dry provisions; module control. 12.000" overall length 9.000" overall width diffuser, rectangular, t-10 ventilation
01-505-0178
Air Register
Used on los angeles class ssn (688); ventilation - combat systems electronics space 1 - starboard. 18.000" overall length 12.000" overall width diffuser, duct, ventilation
01-505-0182
Air Register
Used on los angeles class ssn (688); ventilation - radio room & ships office;. 15.000" overall length 15.000" overall width diffuser, air 3-way, t-25 ventilation
01-505-0183
Air Register
Used on los angeles class ssn (688); ventilation - combat system electronics space 2; module control. 12.000" overall length 12.000" overall width diffuser, duct, t-44 ventilation
01-505-0185
Air Register
Used on los angeles class ssn (688); ventilation - wardroom, pantry, washaroom, stateroom 1 & passageway; module control. 9.000" overall length 9.000" overall width diffuser, rectangular, t-16
01-505-0217
Air Register
Used on los angeles class ssn (688); ventilation - crews mess & dry provisions; module control. 12.000" overall length 9.000" overall width diffuser, rectangular, t-43 ventilation
01-505-0219
Air Register
Used on los angeles class ssn (688); ventilation - torpedo room & weapons launcher hydraulic space; starter motor. 12.000" overall length 12.000" overall width diffuser, duct, t-13 ventilation
01-505-0220
Air Register
Used on los angeles class ssn (688); ventilation - torpedo room & weapons launcher hydraulic space; starter motor. 15.000" overall length 12.000" overall width diffuser, air, t-32 ventilation
01-505-0222
Flue Damper
Used on typical gaylord auxiliary exhaust terminal. 15.000" overall width damper assembly
01-505-0223
Air Register
Used on los angeles class ssn (688); ventilation - torpedo room & weapons launcher hydraulic controls; starter motor. 6.000" overall length 6.000" overall width diffuser, air, t-03 ventilation
01-505-0228
Air Register
Used on los angeles class ssn (688); ventilation - miscellaneous electronic equipment space & passageway; module control. 12.000" overall length 9.000" overall width diffuser, rectangular, t-27 ventilation
01-505-0238
Air Register
Used on los angeles class ssn (688); ventilation - miscellaneous electronic equipment space & passageway; module control. 12.000" overall length 6.000" overall width diffuser, rectangular, t-24 ventilation
01-505-0244
Air Register
Used on los angeles class ssn (688); ventilation - recirculate system r(7) - engine room upper level; starter motor. 18.000" overall length 9.000" overall width diffuser, duct, air 2-way, t-85
01-505-0252
Air Register
Used on los angeles class ssn (688); ventilation - recirculate system r(11) - engine room upper level; starter motor. 15.000" overall length 12.000" overall width diffuser, duct, air 2-way, t-88 ventilation
01-505-0256
Air Register
Used on los angeles class ssn (688); ventilation - recirculate system r(13) - engine room upper level; starter motor. 15.000" overall length 12.000" overall width diffuser, air 2-way, t-87 ventilation
Page: 171 ...