NSN 4520-01-184-6468 NIIN 011846468 — Duct Type Stationary Heater

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
4520-01-184-6468
4520011846468
Description:
HEATER,DUCT TYPE,STATIONARY
NSN Assigned:
20-JUL-84
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

4520-01-184-6468 Specification Set by the OEM (see RNCC code 3)

Mounting Type AAXX:

ventilation duct

Heat Medium Type ABAM:

air

Width ABGL:

11.500in.

Current Type ACDC:

ac

Depth AEJZ:

15.562in.

Operating Control Type ALYC:

any acceptable

Current Rating In Amps AMPS:

10.4

Heating Element Type BDXJ:

electric nonimmersion

Inclosure Material CQSJ:

steel corrosion resisting

Heat Delivery Rate CQXD:

15558.7 british thermal unit

Voltage In Volts ELEC:

440.0

Phase FAAZ:

three

Frequency In Hertz FREQ:

50.0 or 60.0

Height HGTH:

4.500in.

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
MIL-H-22594
Cage Code:
81349
RNCC:
4
RNVC:
1
DAC:
4
RNAAC:
75
Status:
A
MSDS:
SADC:
Part Number:
106-553123-001
Cage Code:
65586
RNCC:
3
RNVC:
2
DAC:
E
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
106-553123-000
Cage Code:
65586
RNCC:
D
RNVC:
9
DAC:
A
RNAAC:
AX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
17014
FIIG:
A01300
Concept No.:
1
App. Key:
E
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "HEATER,DUCT TYPE,STATIONARY"

A device capable of producing heat from gas, liquid fuel, or an electrical heating element designed for permanent installation in sheet metal ducts of a forced air circulating system. It consists of (1) a finned, steel burner tube, a combustion air blower, a control panel, and a constant level fuel supply system or (2) a device having a heating element which when connected to an electrical source, directly imparts heat. It may be provided with a flanged outer casing to facilitate mounting in planned or existing duct work. Circulation of the heated air is achieved by use of a blower or fan not integral with the heating unit.

4520-01-184-6468 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
A
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) A

Item does not contain precious metal.

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
SMS
SOS:
MMAC:
MCC:
Source of Supply (SOS) SMS

Defense logistics agency, enterprise business systems

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.