NSN 4320-00-449-4344 NIIN 004494344 — Centrifugal Pump Unit

NSN
Item Name
Assigned
DEMIL
Shelf Life
UOM
Using Services
NSN:
4320-00-449-4344
4320004494344
Description:
PUMP UNIT,CENTRIFUGAL
NSN Assigned:
16-FEB-72
DEMIL:
NO
Shelf Life:
N/A
UOM:
1 EA
Using Services:
Navy, Air Force

Price Quote Get an up to date pricing and availability quote for this product. Order online or over the phone.

Part Number:
Quantity Requested:
Your Email:
Full Name:
Contact Phone:
Company:

Quality Commitment

Serving our customers with quality and safety first.

  •   AS9120 Certified
  •   Audited supply chain
  •   ITAR Registered
  •   DDTC Registered
  •   HAZMAT Certified
  •   Customer service objectives
  •   Every product 100% inspected
AS9120 Certified by SAI Global

4320-00-449-4344 Specification Set by the OEM (see RNCC code 3)

Prime Mover Quantity AAXH:

1

Prime Mover Cooling Medium AAXS:

air

Stage Quantity AAYD:

1

Intake Connection Quantity AAYT:

1

Intake Connection Type AAYU:

threaded internal

Discharge Connection Quantity AAYV:

1

Discharge Connection Type AAYW:

threaded internal

Current Type ACDC:

ac

Media For Which Designed ACKL:

water, fresh

Environmental Protection ADZC:

dripproof

Pump Quantity AENC:

1

Cooling Method AENK:

self ventilated

Maximum Discharge Flow Rate AHYV:

40.0 gallons per minute

Discharge Pressure AHYW:

125.0 pounds per square inch gage

Total Head AHYX:

11.000 feet

Operating Speed At Rated Capacity AHYZ:

1750.0 revolutions per minute

Pumping Element Operating Position AHZA:

horizontal

Centrifugal Pump Design AHZE:

radial flow

Centrifugal Pump Impeller Quantity AHZF:

1

Centrifugal Pump Impeller Suction Type AHZG:

single

Prime Mover Type AKDJ:

electric motor

Inclosure Type AKNA:

open

Discharge Connection Thread Size And Series/type Designator ASAZ:

1.500-11-1/2 npt

Intake Connection Thread Size And Series/type Designator ASWT:

1.500-11-1/2 npt

Voltage In Volts ELEC:

115.0

Phase FAAZ:

single

Frequency In Hertz FREQ:

60.0

Cross Reference Parts Part numbers that meet the specification outlined on this page and set by the OEM

Part Number
Cage
RNCC
RNVC
DAC
RNAAC
Status
MSDS
SADC
Part Number:
HVBNFI WITH 1-1/2 IN FLANGES
Cage Code:
06631
RNCC:
3
RNVC:
9
DAC:
6
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
111B1 1/4 AND 111B1 1/2
Cage Code:
59015
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
H-32B-1 1/4 AND H-32B-1 1/2
Cage Code:
52694
RNCC:
5
RNVC:
2
DAC:
6
RNAAC:
AX
Status:
A
MSDS:
SADC:
Part Number:
B1 1/2HV
Cage Code:
06631
RNCC:
5
RNVC:
9
DAC:
E
RNAAC:
AX
Status:
A
MSDS:
SADC:

Identification Item Identification Guide (IIG) and Item Name Code (INC)

INC
FIIG
Concept No.
App. Key
Cond. Code
Status
INC:
17988
FIIG:
A19400
Concept No.:
App. Key:
C
Cond. Code:
1
Status:
A

Definition Definition of approved item name (AIN): "PUMP UNIT,CENTRIFUGAL"

An assembled unit consisting of a commonly mounted centrifugal pump(s), prime mover(s), and the necessary components to provide for a complete operation.

4320-00-449-4344 Material Hazmat, Precious Metals, Criticality, Enviroment, and ESD

HMIC
PMIC
ESD
ENAC
ADPE
CRITL
HMIC:
N
PMIC:
U
ESD:
ESD:
ADPE:
CRITL:
X
Hazmat (HMIC) N

Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

Precious Metals (PMIC) U

Precious metal content is unknown

Criticality X

The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.

  Identification Codes

HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.

PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.

ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.

ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.

CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.

Material Management Material categorization and source of supply

SOS
SMIC
MMAC
MCC
SOS:
SMS
SOS:
MMAC:
MCC:
Source of Supply (SOS) SMS

Defense logistics agency, enterprise business systems

  Material Codes

SOS: Source of Supply. A three position code or routing identifier code (ric), which identifies the source of supply activity.

SMIC: Special Material Indicator Code. A two position code, which categorizes material on the basis of requirements for source or quality control, technical design or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling.

MMAC: Material Management Aggregation Code. A two position code that identifies an item of supply to be managed by a specific activity manager.

MCC: Material Echelon Code. A two position code employed by the marine corps in classifying items into categories by materiel category and procurement echelon. the alphanumeric management code is in the first position and identifies the materiel category

IMC: Denotes wether items shall be subjected to integrated management under the defense supply agency or retained by the individual military service or other department of defense components for their management. Assigned by th activity responsible for item management coding.