Serving our customers with quality and safety first.
1
100
air
130.000 cubic feet per minute
125.000 pounds per square inch gage
single
air
air
air
automatic
base
single acting
vertical design
2
11.00 cubic feet
1
52.56in.
40.13in.
99.00in.
electric motor
high temperature shutdown switch and relief valve
fungus resistant treatment
208.0 ac
380.0 deg fahrenheit discharge
three
reduced voltage, auto TRANSFORMED-Type motor starter w/65 and 80 pct taps
60.0
the air compressor is a stationary, ELECTRIC-Motor driven, DOUBLE-Stage unit intended for heavy duty service in installations where a steady volume of air in a pressure range of 5 to 125 psi is required
af to. 34Y1-131-1
81349-MIL-C-17596 government specification
MB-5 type
as modified by pac feat
An assembled unit consisting of a commonly mounted reciprocating compressor(s) and a prime mover(s). For items with additional equipment which extends the function of the unit beyond the delivery of compressed air or gas, see pneumatic tool and compressor outfit, or more specific names, as applicable. Excludes auxiliary set, engine driven.
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Item does not contain precious metal.
Represents items with no adp components
The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application.
HMIC: Hazardous Material Indicator Code. A one position code that identifies a hazardous item.
PMIC: Precious Metal Indicator Code. A one position code which identifies items that have precious metals as part of their content. precious metals are those metals generally considered to be uncommon, highly valuable, and relatively superior in certain properties such as resistance to corrosion and electrical conductivity.
ESD: Electrostatic Discharge. Indicates if an item is susceptible to electrostatic discharge or electromagnetic interference damage. electrostatic discharge damage occurs when an accumulation of static electricity generated by the relative motion or separation of materials is released to another item by direct contact. electromagnetic interference damage occurs when an item comes into proximity with an electrostatic or magnetic field.
ENAC: Enviromental Attribute Code. Identifies items with environmentally preferred characteristics.
CRITL: Criticality Indicator Code. Indicates an item is technically critical by tolerance, fit, application, nuclear hardness properties, or other characteristics.