Serving our customers with quality and safety first.
2b
RIGHT-Hand
hexagon
0.219in. and 0.281in. ⁓9/32"
1.250in. ⁓1-1/4"
unef
20
0.875in. ⁓7/8"
flat
nut face intersection points are bevelled at 19.0 deg. min.-21.0 deg. max. on both sides; nut has three equally spaced holes 0.109 in. min.-0.150 in. max. from either side measuring 0.047 in. min.-0.077 in. max. in diameter
copper alloy 360
QQ-B-626 fed spec single material response
cadmium
QQ-P-416, type 2, class 1 fed spec single treatment response
Copper alloy 360
20
Right-hand
2b
Schedule B number: 7415290000
Copper screws, nuts, bolts, rivets, and other fasteners not threaded
FSC 5310 ⁓ Nuts and washers
Note-nuts and washers, including specially designed, are to be classified in this fsc. a. nuts are a small metal block made in a variety of shapes such as square and hexagonal which is drilled and internally threaded. b. washers are a perforated piece of metal, leather, or other materials of various shapes or forms. they are used primarily as a seat for a bolt, nut, screw, rivet or nail to distribute pressure and prevent endwise motion over an area and/or to prevent movement between two parts by means of restraining features created by the shape of its edges.
Excluding bearing thrust washers (fsc 3120); shims (fsc 5365); ring spacers (fsc 5365); plate spacers (fsc 5365); lock rings (fsc 5365).
cadmium surface treated nut face intersection points are bevelled at 19.0 deg. min.-21.0 deg. max. on both sides; nut has three equally spaced holes 0.109 in. min.-0.150 in. max. from either side measuring 0.047 in. min.-0.077 in. max. in diameter 20 thread quantity per inch right-hand 2b thread class
Nothing similar to this part number was found in our inventory
A nut, flat on top and bottom having 6 flat sides. for items which have internal tapered or straight (parallel) pipe threads, specific electrical conduit size designation, and which when installed, provide a method of tightening to lock the connection, see locknut, electrical conduit. see also locknut, tube fitting. for items having a thickness (or height) exceeding two times the width across the flats, use post, electrical-mechanical equipment. (when height or thickness and/or width across the flats is designated as a tolerance dimension, the maximum dimension will be used to determine compliance.)